Operating Instructions
CAUTION!
Damage to the manual operation by pressing and simultaneously turning..
► Manual operation do not press and turn at the same time.
Switch positions of the manual operation:
3.
Switch manual operation with a screwdriver (touch function or latching function).
4.
Check the correct position of the gasket (housing jacket).
5.
After adjustment, screw the housing jacket of the type SPC Lite positioner back on.
NOTE!
Breakage of the pneumatic connecting pieces due to rotational effect.
► When unscrewing and screwing in the housing jacket, do not hold against the actuator of the valve, but against the basic housing.
CAUTION!
Damage or functional failure due to ingress of dirt and moisture.
► To comply with protection rating IP65/IP67, screw the housing jacket in as far as it will go.
2
1
3
No. Designation
1
Normal position
2
Latching function: 90° rotated = latching changeover
3
Touch function: Press = brief actuation
Type SPC Lite positioner
31