Operating Instructions
7.2
Disconnect electrical connections
► Remove the circular connector.
DANGER!
Risk of injury due to power supply.
► Before intervening in the device or the system, switch off the power supply and secure it against being switched on again.
► Observe the applicable accident prevention and safety regulations for electrical devices.
7.3
Type SPC Lite positioner disassembly
1
1.
Loosen fixing screws.
2.
Type SPC Lite Disconnect the positioner from the actuator and remove it.
8
Disposal
NOTE!
Environmental damage due to equipment parts contaminated by media.
► Dispose of the device and packaging in an environmentally friendly manner.
► Comply with applicable disposal regulations and environmental regulations.
1
1
No.
Designation
1
Electrical connection housing
2
Circular connector
No.
Designation
1
Fixing screws
Type SPC Lite positioner
33