11. Technical data
Supply voltage
Motor protection
Type of protection
Winding category
Temperature category
Media temperature
Ambient temperature
Maximum operating pressure
Noise
Leakage current
Power consumption
when pump switched off
Performance factor cos-phi
EMV (electromagnetic
compatibility)
12. Disposal
This ModulA circulation pump was developed with sustainability in mind. This also includes
waste prevention and recyclability of materials. This product as well as its parts must be
disposed of according to the local regulations.
1×230 V ±10%, 50/60 Hz, PE
External motor protection is not required
IP 44 (EN 60529)
Insulation category F
TF 110 (EN 60335-2-51)
+15°C to +110°C (ModulA RED)
+15°C to +85°C (ModulA BLUE)
max. 40°C
In transportation: –40 °C up to +70 °C
The maximum operating pressure is given on the nameplate:
PN 6:
6bar
PN 10: 10bar
PN 16: 16bar
Sound pressure level under 43 dB(A)
The mains filter of the pump causes a leakage current
to the earth of <3.5 during operation
<3W
The ModulA has an integrated performance factor correction filter
(PFC). This ensures that cos-phi is always between 0.98 and 0.99
and is therefore kept very close to the ideal value 1.
EN 55014-1:2006, EN 55014-2:1997,
EN 61000-3-3:2008 and EN 61000-3-2:2006
english
37
|