Electrical connection
WARNING
9
RISK OF ELECTRIC SHOCK
Parts inside the appliance can have sharp edges.
The connection cable can be damaged. Do not
bend or pinch connection cables during installation.
Before connecting the appliance, turn off power circuit at
service panel and lock out panel before wiring this
appliance.
Requirement: 120 VAC, 60 Hz 15 A. (see rating plate).
The appliance complies with protection class 1 and must
only be operated in conjunction with a protective
conductor terminal.
An all-pole isolating switch with at least a 3 mm contact
gap must be fitted in the installation. This must remain
accessible after installation.
Only a qualified electrician who takes the appropriate
regulations into account may lay or replace the
connecting cable.
Follow all standards, regulations and laws.
Before You Begin
Tools and Parts Needed
Measuring tape
Pencil
Phillips screwdriver (Posidrive) #2
Drill with the following bits: 5/16" (7.9 mm) and 3/8"
(9.5 mm)
Spirit-level
Aluminum tape (DO NOT use insulating tape)
Exhaust channel (configuration depends on the
installation situation)
Additional sheet metal screws (if necessary for
installation of the exhaust air duct)
Saw
8
Ensure that the electrical connection meets the
requirements of the latest version of all applicable
standards, regulations and laws in the appropriate country,
especially the following standards: National Electrical Code,
ANSI/NFPA 70*, or CSA Standards C22.1-94, Canadian
Electrical Code, Part 1 and C22.2 No.0-M91**.
Have a qualified electrical technician check the
grounding of the appliance.
Do not ground to a gas line.
No fuse protection in the neutral or grounding circuit.
Keep these installation instructions. Only connect the
appliance with a copper conductor. If possible, connect
the appliance to a metal cable guide directly to the fuse
box.
Ensure that the wire diameter meets the requirements of
the latest version of all applicable standards and laws in
the appropriate country, especially the following
standards: National Electrical Code, ANSI/NFPA 70*, or
CSA Standards C22.1-94, Canadian Electrical Code, Part
1 and C22.2 No.0-M91**.
Put a protecting hose that is listed in the U.L. or C.S.A. on
both ends of the connecting cable, that is, on the
appliance and on the fuse box.
For copies of the standards listed, contact:
* National Fire Protection Association Batterymarch Park
Quincy, Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
Parts Included
Extractor hood with fan, back-pressure flap
Lamp, already installed
Metal grease filter
Flue duct
Drill template
1x angle bracket for the flue duct
Installation manual and instructions for use
6x screws, 5x45 mm
8x screws, 4x8 mm
2x washers
2x hollow wall plugs, 8x40 mm
4x hollow wall plugs, 10x50 mm
Torx adapter, 10 & 20