Environmental conditions
Make sure that the place for attachment is firm
enough to withstand the strain of the device.
Electrical power supply installation
Ensure that the current connection and power installation meet the following requirements:
• The nominal voltage of the installation must
coincide with that of the control board.
• The installation must be able to support the
power consumed by all the automatic key
devices.
• The installation must be earthed.
• The electrical installation must comply with
low voltage regulations.
• The installation elements must be properly
secured and in a good state of conservation.
4
INSTALLATION IN UP-AND-OVER DOOR
Install the guide and the operator
UNPACKING AND INSTALLATION
This device is not suitable for installation in
inflammable or explosive environments.
Check that the admissible environmental
temperature range for the operator and
control board is suitable for the location.
• The direct connection point must be high
enough to be out of the reach of children.
• The
facility
must
disconnection
device
opening distance that allows complete
disconnection
under
established in overvoltage category III.
If the electrical installation does not comply
with the foregoing requirements, repair before
installing the automatic key device.
O
The door guide (A) and the chain guide (2) must
be separated by 50 mm (see the details in the
figure).
1 Position the chain tensioner equipment (1) in the
guide (2).
2 Introduce the drive block (3) in the upper part of the
guide.
3 Position the countershaft:
Single drive: 4.a
Dual drive: 4.b
4 Secure the operator (5a) or (5b) in the countershaft.
5a: IZ1C, IZ4C, IZ4DC
5.b: IZS1, IZS4, IZS4D
5 Install the drive chain (6) and the elevation chain (7).
6 Tighten the elevation chain (7) using the tightener
screw (1a).
7 Position all the equipment on the pillar.