REQUIRED DAILY TESTING
To reduce the risk of injury to your-
WARNING
self and others, test the tool before
beginning work each day or if the tool is dropped,
received a sharp blow, been run over, etc. Com-
plete the following checklist IN ORDER. If the tool
does not work as it should, contact a MILWAUKEE
service facility immediately.
Always point tool away from yourself and others.
1. Remove battery pack.
2. WARNING! Always point the tool away from your-
self and others when installing fasteners. Failure
to do so could result in injury.
3. Check all screws, bolts, nuts, and pins on the tool.
Any loose fasteners must be tightened.
4. Pull back the fastener pusher on the magazine
(to override the Reload Indicator) and press the
workpiece contact against a workpiece. It must
move smoothly.
5. With the workpiece contact pressed against the
workpiece, pull the trigger. It must move smoothly.
6. Insert battery pack.
7. Select the Single Sequential Actuation Operation.
Without pulling the trigger, pull back the fastener
pusher on the magazine (to override the Reload
Indicator) and press the workpiece contact against
a workpiece. The tool must not operate.
Holding the workpiece contact away from the work-
piece, pull back the fastener pusher on the maga-
zine (to override the Reload Indicator). Pull and hold
the trigger for 5 seconds. The tool must not operate.
Continue to pull and hold the trigger and push the
workpiece contact against a workpiece. The tool
must not operate.
Without pulling the trigger, pull back the fastener
pusher on the magazine (to override the Reload In-
dicator) and press the workpiece contact against a
workpiece. Pull the trigger. The tool must operate.
Release the trigger. The striker must move up.
8. Select the Contact Actuation Operation.
Holding the workpiece contact away from the
workpiece, pull back the fastener pusher on the
magazine (to override the Reload Indicator) and
pull the trigger. The tool must not operate.
Continue to pull and hold the trigger and push the
workpiece contact against a workpiece. The tool
must operate.
9. If all previous tests work properly, set the tool for your
work. Select the operation and load fastener strips.
10. Set the depth of drive according to the "Setting
the Depth of Drive" section.
11. If all tests operate properly, the tool is ready for
use. Repeat these tests before use each day or if
the tool is dropped, received a sharp blow, been
run over, jammed, etc.
MAINTENANCE
To reduce the risk of injury, always
WARNING
unplug the charger and remove the
battery pack from the charger or tool before
performing any maintenance. Never disassemble
the battery pack, charger, or tool, except as pro-
vided in these instructions. Contact a MILWAUKEE
service facility for all other repairs.
Maintaining Tool
Keep your tool, battery pack and charger in good
repair by adopting a regular maintenance program.
Inspect your tool for issues such as undue noise,
misalignment or binding of moving parts, breakage of
parts, or any other condition that may affect the tool
operation. Return the tool, battery pack, and charger
to a MILWAUKEE service facility for repair. After six
months to one year, depending on use, return the
tool, battery pack and charger to a MILWAUKEE
service facility for inspection.
If the tool does not start or operate at full power with
a fully charged battery pack, clean the contacts on
the battery pack. If the tool still does not work prop-
erly, return the tool, charger and battery pack, to a
MILWAUKEE service facility for repairs.
To reduce the risk of personal in-
WARNING
jury and damage, never immerse
your tool, battery pack or charger in liquid or
allow a liquid to flow inside them.
Clean dust and debris from any vents. Keep tool
clean, dry and free of oil or grease. Use only mild
soap and a damp cloth to clean, since certain clean-
ing agents and solvents are harmful to plastics and
other insulated parts. Some of these include gasoline,
turpentine, lacquer thinner, paint thinner, chlorinated
cleaning solvents, ammonia and household deter-
gents containing ammonia. Never use flammable or
combustible solvents around tools.
For repairs, return the tool, battery pack and charger
to the nearest authorized service center.
ACCESSORIES
Use only recommended accesso-
WARNING
ries. Others may be hazardous.
For a complete listing of accessories, go online to
www.milwaukeetool.com or contact a distributor.
SERVICE - UNITED STATES
1-800-SAWDUST
Monday-Friday, 7:00 AM - 6:30 PM CST
www.milwaukeetool.com
or visit
Contact Corporate After Sales Service Technical
Support with technical, service/repair, or warranty
questions.
Email: metproductsupport@milwaukeetool.com
B e c o m e a H e a v y D u t y C l u b M e m b e r a t
www.milwaukeetool.com to receive important
notifications regarding your tool purchases.
7
Cleaning
Repairs
(1.800.729.3878)