3 Connect the DHW outlet pipe (960 mm tube length) (3/4") by
its elbow end to the DHW outlet connection (hot water from
the tank). Take out the other end by the tank's hole at the
back side.
DHW inlet connection
(cold water to the tank)
(Front bottom view)
DHW inlet connection
(cold water to the tank)
3.1)
32
DHW outlet connection
(Hot water from the tank)
DHW outlet connection
(hot water from the tank)
PMML0291A rev.2 - 09/2014
3.2)
4 Connect the DHW inlet pipe (1045 mm tube length) (3/4") by
its elbow end to the DHW outlet connection (cold water to the
tank). Take out the other end by the tank's hole at the back
side.
4.1)
4.2)