PROBLEM
Engine surges or stumbles.
Engine starts and shuts off
immediately.
Fuel leaks from drain hoses.
* Engine speed increases and decreases — This is normal as generator starts up and loads vary.
Instruction Manual for Portable Generator
CAUSE
1. Choke is opened too soon.
2. Carburetor is running too rich or too lean.
3. Dirty fuel filter.
1. CO PROTECT shut-off due to accumulating
carbon monoxide if a RED light blinks on the
side panel badge.
2. CO PROTECT shut-off due to a system
fault if a YELLOW light blinks on the side
panel badge.
3. Contaminated fuel.
4. Defective low oil level switch.
1. Carburetor drain in bowl is not closed.
CORRECTION
1. Contact IASD.
2. Contact IASD.
3. Replace fuel filter.
1. Follow all Safety Instructions and relocate
generator to an open area outside, far away
from windows, doors and vents.
2. Start to confirm YELLOW light blinks when/if
generator shuts-off. If CO PROTECT contin-
ues to fault and shut-off, contact IASD.
3. Contact IASD.
4. Contact IASD.
1. Turn valve clockwise to close.
Maintenance