Descargar Imprimir esta página

Teac TN-5BB Manual Del Usuario página 9

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 23
Dust cover
Attaching the dust cover
Dust cover
Main unit
Hinge
1
Insert the hinges completely into the
hinge holders at the left and right ends
of the back of the main unit.
2
Align the tops of the hinges with the
dust cover hinge holders and insert
them.
o Close the dust cover during playback. Since doing
this prevents skipping caused by unintended contact
and blocks external sound pressure, it makes noise
less likely to occur.
o Do not open or close it when a record is playing.
Doing so could, for example, cause the stylus to skip.
o Keep it closed whenever possible to keep dust out.
Removing the dust cover
Hold both edges of the dust cover and lift it slowly to remove it
along with the hinges from the unit. Then, remove the hinges
from the dust cover.
Opening and closing the dust cover
Opening
Hold the front edge of the dust cover and gently lift it open
completely until it stops.
The dust cover will stay open in this position.
Closing
Gently lower the dust cover until it is closed.
V Be careful not to pinch your fingers, for
example, when opening and closing the
dust cover.
8
Notes about record styluses
o If the stylus becomes bent (damaged), it will no longer
be able to accurately trace the groove. Since a bent stylus
could also damage records and cause malfunction, handle
styluses carefully.
o Always use a commercially-available stylus cleaner to clean
a stylus. Use of anything other than a stylus cleaner could
damage the stylus.
Replacing the stylus
If the tip of the stylus becomes worn, not only will it worsen
the sound quality, it could also damage records. After about
1000  hours of playback time, replace the stylus with one that
we specify.
The cartridge installed in the product is an Ortofon 2M Red
MM-type cartridge.
When used normally, the 2M Red stylus should be replaced
about every 1000  hours. Please purchase a commercially-
available 2M Red replacement stylus.
o Follow the replacement instructions in the manual of the
replacement stylus.
ATTENTION
o Since loud noises could suddenly occur, put the unit into
standby before changing the stylus.
o Be careful not to hurt your hand or the equipment.
o Be careful not to allow small children to accidentally swal-
low styluses.
o Be aware that bent styluses, for example, that result from
insufficient customer caution or an outside cause are not
covered by the warranty.
Changing the cartridge
To change the cartridge, first remove the headshell from the
tonearm.
o The cartridge installed in the product is an Ortofon 2M Red
MM-type cartridge.
o We recommend that you attach the protective cover to the
cartridge before proceeding.
Headshell
Screws
Nut
(inside the cartridge)
Shell leads
Cartridge
1
Disconnect the shell lead terminals from
the cartridge.
2
Loosen the screws and remove the
cartridge.
3
Attach the new cartridge and tighten
the screws.
o Use screws that are suitable for the cartridge.
See the illustration below for the position of the screws
when attached.
52.8 ±0.5 mm
NOTE
To adjust the cartridge attachment position more accu-
rately, follow the procedures in the following "Cartridge
alignment (overhang adjustment)" section.
4
Connect the shell lead terminals to the
cartridge.
o The signals and colors of the shell leads are shown
below.
Signal
Color
Left channel +
White
Left channel −
Blue
Right channel +
Red
Right channel −
Green
5
Balance the tonearm and adjust the
tracking force.
Follow the procedures in "Balancing the tonearm and
adjusting the tracking force" on page 4.

Publicidad

loading

Este manual también es adecuado para:

Tn-5bb-m/b