Heat Pump Model
Model: FTXS 25/35 RXN 25/35
COOLING
50
46
43
40
30
20
10
0
10
14 15
INDOOR TEMP (°CWB)
Model: FTXS 50/60 RXN 50/60
COOLING
50
46
43
40
30
20
10
0
-10
-20
10
14 15
INDOOR TEMP (°CWB)
1.
Open the front panel.
•
Hold the panel at the recesses on the main unit
(2 recesses on right and left sides) and lift it until it
stops.
2.
Pull out the air filters.
•
Push a little upwards the tab at the center of each air
filter, then pull it down.
OPERATING RANGE
19 20
23
25
DB: Dry bulb
19 20
23
25
DB: Dry bulb
AIR FILTER
Recess on
main unit
20
18
10
0
-10
-15
-20
1
0
15
INDOOR TEMP (°CDB)
WB: Wet bulb
20
18
10
0
-10
-15
-20
1
0
15
INDOOR TEMP (°CDB)
WB: Wet bulb
3.
Clean or replace each filter.
•
When shaking off remaining water, do not wring the
filter.
4.
Set the air filter and close the front panel.
•
Insert claws of the filters into slots of the front panel.
Close the front panel slowly and push the panel at the
3 points. (1 on each side and 1 in the middle.)
•
The air filter have a symmetrical form in the horizontal
direction.
FRONT
1-14
HEATING
20
2
5
2
7
3
0
HEATING
20
2
5
2
7
3
0