Daikin FTXS25A Manual De Instalación página 7

Publicidad

Idiomas disponibles

Idiomas disponibles

Indoor Unit
Front panel
50mm or more from walls
(on both sides)
Outdoor Unit
Where a wall or other obstacle is in the path of outdoor unit's intake or exhaust airflow, follow the installation guidelines
below.
For any of the below installation patterns, the wall height on the exhaust side should be 1200mm or less.
Wall facing one side
More than 50
1200 or
Side View
INSTALLATION DIAGRAM
55mm or more from ceiling
M4 x 12L
Air filter
n Opening service lid
Service lid is opening/closing
type.
n Opening method
1) Remove the service lid
2) Pull out the service lid
3) Pull down.
INSTALLATION OF THE OUTDOOR UNIT (25/35)
More than 100
less
Caulk pipe
hole gap
with putty.
Service lid
screws.
diagonally down in the
direction of the arrow.
Wall facing two sides
More
than 100
More than 50
Wall facing three sides
More than 50
Top View
1-5
Cut thermal insulation pipe to an
appropriate length and wrap it with
tape, making sure that no gap is left
in the insulation pipe's cut line.
Wrap the insulation pipe
with the finishing tape
from bottom to top.
More than 150
More than 50
Top View
More than 150
More than 300
Unit : mm