2. REQUIREMENTS PRIOR TO INSTALLATION
ALL LOCAL STANDARDS, INCLUDING NATIONAL AND EUROPEAN REGULATIONS MUST BE COMPLIED WITH
UPON INSTALLATION OF THE EQUIPMENT.
THE INSTALLATION MUST BE PERFORMED BY A PROFESSIONAL. FAILURE TO COMPLY WITH THIS CLAUSE
SHALL EXONERATE THE MANUFACTURER FROM ANY RESPONSIBILITY.
2.1 Ground. Make sure the ground where the appliance will be placed is able to support the weight of the device. If not,
you will need a load spreading plate for the equitable distribution of the equipment's weight. In case of doubt, please
consult a specialist.
2.2 Flue liner. It is mandatory to have a smoke-tight Flue liner going from the connecting point of the base to the outside
in observation of the smoke pipe diameter. The good condition and suitability of this smoke pipe must be certified
by a professional and must also observe the relevant national regulations. This Flue liner should not be shared
with other devices (see Table 1.1 Technical specifications).
2.3. Type of appliance. This fireplace is exempt, so it doesn't need any revetment.
2.4 Security insulation and security distance. Any fragile or flammable element, textiles, electronic devices, wood,
wallpaper, glass, chalk paper, etc., must be separated from the device observing the minimum distance described in
Table 1.1 Technical specifications. Special attention should be paid to equipment installed in contact with wood or similar:
we must prevent or avoid the possibility of hot air impacting directly on the wood: in such case, it shall be insulated
accordingly.
2.5 Air supply. Air should be provided to the room where the appliance is installed. This is especially relevant when
outside air is not used and also when the door is opened for reloading with logs. This entry cannot be less than 225 cm
Also note the simultaneous operation with other ventilation devices and / or heating such as exhaust fans, heat pumps,
etc. In these cases, the extraction must be compensated with a corresponding air entry from outside.
2.6. Changes to the device. Any intended change to the equipment must be authorized in writing by Manufacturas
Rocal, S.A. We also recommend using only original spare parts or parts recommended by Manufacturas Rocal, S.A.
3. INSTALLATION
3.1 Installation process. To proceed with the installation, follow the steps outlined in Section III of the ANNEXED
document.
. USE AND OPERATION
4
4.1 Fuels authorized by the manufacturer. The appliance should not be used as an incinerator and the use of fuels
other than those authorised by the manufacturer are prohibited, including lighting liquids or gels. Only natural wood logs
are authorized as fuel and it is not advisable to use resinous woods.
CAUTION:
- The maximum load allowed by the manufacturer, the measurements of the logs and the
height of the reload must be respected.
- Do not touch or manipulate any part of the appliance when in operation without a protection
glove.
4.2 Pilot fire lighting. For a reasonable period of time, approximately 24 hours, it must not exceed 50% of the Maximum
load allowed by the manufacturer. Before lighting the fire, ensure that nothing delivered with the equipment has stayed
inside (such as gloves, spray paint ...)
4.3. Combustion control. The appliance has mechanisms to regulate combustion.
4.3.1. Primary register. The primary register is used to control the air entering the combustion chamber through the
base of the fire, through the fire grate. The primary register should be used mainly for lighting and, if necessary, to aid
combustion. To locate the register control handle and to know how to use it see picture "D.3" on page 14 of the
ANNEXED document.