Notice to installing contractor: Instructions must remain with installation.
Trusted. Tested. Tough.
DATE INSTALLED:
MODEL NUMBER:
Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies.
1. Inspect all materials. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before using.
DO NOT remove the test/oil fill plugs from the pump.
2. Carefully read the literature provided to familiarize yourself with specific details regarding installation and use. These materials should be retained
for future reference.
1. Make certain that the receptacle is within the reach of the pump's
power supply cord. DO NOT USE AN EXTENSION CORD. Extension
cords that are too long or too light do not deliver sufficient voltage to
the pump motor and could present a safety hazard if the insulation were
to become damaged or the connection end were to fall into a wet or
damp area.
2. Check to be sure your power source is capable of handling the voltage
requirements of the motor, as indicated on the pump name plate.
3. Make sure the pump electrical supply circuit is equipped with fuses
or circuit breakers of proper capacity. A separate branch circuit is
recommended, sized according to the "National Electrical Code" for
the current shown on the pump nameplate.
4. Testing for ground. As a safety measure, each electrical outlet should
be checked for ground using an Underwriters Laboratory Listed circuit
analyzer which will indicate if the power, neutral and ground wires are
correctly connected to your outlet. If they are not, call a qualified licensed
electrician.
5. For Added Safety. Pumping and other equipment with a 3-prong
grounded plug must be connected to a 3-prong grounded receptacle.
For added safety the receptacle may be protected with a ground-fault
circuit interrupter. When a pump needs to be connected in a watertight
junction box, the plug can be removed and spliced to the supply cable
with proper grounding. For added safety this circuit may be protected
by a ground-fault circuit interrupter. The complete installation must
comply with the National Electrical Code and all applicable local codes
and ordinances.
6. FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS
POWER SOURCE BEFORE HANDLING. Single phase pumps are
supplied with a 3-prong grounded plug to help protect you against the
possibility of electrical shock. DO NOT, UNDER ANY CIRCUMSTANCES,
REMOVE THE GROUND PIN. The 3-prong plug must be inserted into
a mating 3-prong grounded receptacle. If the installation does not
have such a receptacle, it must be changed to the proper type, wired
and grounded in accordance with the National Electrical Code and all
applicable local codes and ordinances. Three phase pumps require
motor starting devices with motor overload protection. See FM0486 for
duplex installations.
7. Risk of electric shock. Do not remove power supply cord and strain
relief or connect conduit directly to the pump.
8. Installation and servicing of electrical circuits and hardware should
be performed by a qualified licensed electrician.
9. Pump installation and servicing should be performed by a qualified
person.
10. Risk of electric shock. These pumps have not been investigated for use
in swimming pool and marine areas.
®
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
Tel: (502) 778-2731 • 1 (800) 928-PUMP
INSTALLATION INSTRUCTIONS
MODELS 63 AND 95
PREINSTALLATION CHECKLIST
ALL INSTALLATIONS
SEE BELOW FOR
LIST OF WARNINGS
© Copyright 2023 Zoeller
SAFETY INSTRUCTIONS
TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR MAJOR
PROPERTY DAMAGE, READ AND FOLLOW ALL SAFETY
INSTRUCTIONS IN THIS MANUAL AND ON THE PUMP.
THIS MANUAL IS INTENDED TO ASSIST IN THE INSTALLATION AND
OPERATION OF THIS UNIT AND MUST BE KEPT WITH THE PUMP.
This is a SAFETY ALERT SYMBOL. When you see
this symbol on the pump or in the manual, look for
one of the following signal words and be alert to the
potential for personal injury or property damage.
Warns of hazards that CAN cause serious personal
injury, death or major property damage.
Warns of hazards that CAN cause personal injury
CAUTION
or property damage.
Warns of electrical shock hazards that can cause
serious personal injury, death or major property
damage.
Identifies any terminal which is intended for
connection to and external conductor for protection
against electrical shock in case of a fault, or the
terminal of a protective earth (ground) electrode.
Read operator's manual.
THOROUGHLY REVIEW ALL INSTRUCTIONS AND WARNINGS PRIOR
TO PERFORMING ANY WORK ON THIS PUMP.
MAINTAIN ALL SAFETY DECALS.
REFER TO CAUTIONS AND WARRANTY ON PAGE 2.
Co. All rights reserved.
®
1
FM2895
0823
Supersedes
0418
Visit our website:
zoellerpumps.com
Register your
Zoeller Pump Company
Product on our website:
http://reg.zoellerpumps.com/
NOTICE: VENT HOLE FOR
CHECK VALVE
SEE #1 IN CAUTION SECTION
ON PAGE 2 AND #4 ON PAGE 4