NOTICE TO INSTALLER: Instructions must remain with installation.
Your Peace of Mind is Our Top Priority
Product information presented
here reflects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.
Patent No. 7,203,976
Other Patents Pending
1. Inspect all materials. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before
using. Do Not remove the test plugs from the pump.
2. Carefully read all the literature provided to familiarize yourself with specific details regarding installation and use before
attempting the installation. These materials should be retained for future reference.
SEE BELOW FOR LIST OF WARNINGS
1. To help reduce the risk of electrical shock, a properly
grounded receptacle or control box of grounding type must
be installed and protected by a ground fault circuit interrupter
(GFCI) in accordance with the National Electrical Code and
applicable local codes. Never remove ground pin from
plug.
2. Make certain that the ground fault interrupter protected
receptacle is within reach of the pump's power supply cord. DO
NOT USE AN EXTENSION CORD. Extension cords that are
too long or too light do not deliver sufficient voltage to the pump
motor. But more important, they could present a safety hazard
if the insulation were to become damaged or the connection
end were to fall into a damp or wet area.
3. Make sure the pump's electrical supply circuit is equipped
with fuses or circuit breakers of proper capacity. A separate
branch circuit, sized according to the National Electrical Code
for the current shown on the pump name plate is recommended
(see Note 3).
4. TESTING FOR GROUND. As a safety measure, each electrical
outlet should be checked for ground using an Underwriters
Laboratory Listed circuit analyzer which will indicate if the
power, neutral and ground wires are correctly connected to your
outlet. If they are not, call a qualified licensed electrician.
5. FOR YOUR PROTECTION ALWAYS DISCONNECT PUMP
FROM ITS POWER SOURCE BEFORE HANDLING. If pump
is wired direct, de-energize the circuit at the control box.
Grounded pumps are supplied with a 3-prong grounded plug
to help protect you against the possibility of electrical shock.
DO NOT UNDER ANY CIRCUMSTANCES REMOVE THE
GROUND PIN. To reduce the risk of electrical shock, a properly
grounded receptacle of grounding type must be installed
and protected by a ground fault circuit interrupter (GFCI) in
accordance with National Electrical Code and applicable local
codes.
6. Installation and checking of electrical circuits and hardware
should only be performed by a qualified licensed electrician.
7. According to the state of California (Prop 65), this product
contains chemicals known to the state of California to cause
cancer and birth defects or other reproductive harm.
®
®
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624
QWIK JON
ULTIMA 202 SYSTEMS
®
INSTALLATION INSTRUCTIONS
PREINSTALLATION CHECKLIST
SEE BELOW FOR LIST OF CAUTIONS
1. This unit is not designed to handle any material other than
human waste and toilet paper. The following list includes, but
is not limited to, items that should not be used with this system:
Feminine sanitary products, condoms, cotton balls and swabs,
baby wipes, paper towels, etc.
2. Check to be sure your power source is adequate to handle the
amperage requirements of the motor as indicated on the pump
or unit I.D. tag.
3. All plumbing (discharge and vent lines) must be installed to meet
local codes. Unit must be vented. Do not use an automatic
plumbing vent device. Toilet will not flush.
4. Maximum operating temperature for model 202 must not exceed
130°F (54°C).
5. Do not use cleaning products containing bleach in the toilet
tank, toilet or attached fixtures as they will degrade the pump
seals.
NOTES
SEE BELOW FOR LIST OF NOTES
1. Repair and service should be performed by an Authorized
Service Station only. (Consult Factory.)
2. NOTE: Recommended for installations up to 20' total dynamic
head. Consult Factory if installation is above 15' vertical height
in 1" pipe. Mini-Grinder Pump is designed for use in Qwik
Jon ® Ultima units only. It is not designed for use in any other
application.
3. Mini-grinder pump is rated for 115V, 60 Hz, 7 Amps, .5 HP.
4. NOTE: Pumps with the "UL" mark and pumps with the "US"
mark are tested to UL Standard UL778. CSA Certified pumps
are certified to CSA Standard C22.2 No. 108.Qwik Jon ® Ultima
units only. It is not designed for use in any other application.
5. Model 202 toilet utilizes 1.6 gallons per flush.
6. All fixtures connecting to the system must be on the same floor
level.
REfER TO WARRANTy ON pAgE 2.
SECTION: 6.10.063
Supersedes
visit our web site:
www.zoeller.com
MODEL NO. ____________________
DATE CODE: __________________
DATE INSTALLED: _____________
FM2369
0512
0811

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Zoeller QWIK JON ULTIMA 202

  • Página 1 MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347 visit our web site: SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961 www.zoeller.com Patent No. 7,203,976 (502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624 Other Patents Pending MODEL NO.
  • Página 2 Factory. bathroom application. Washing machines and dishwashers are examples of equipment that we Do Not recommend. 9. DO inspect and test system for proper operations at least every 3 months. © Copyright 2012 Zoeller Co. All rights reserved.
  • Página 3: Service Parts

    10-2123 Tank to Toilet Hardware 017360 017360 Flush valve replacement kit 150658 150658 Fill valve assembly with tube 150823 150823 Flush valve assembly 150824 150824 Flapper with clip and chain 150825 150825 © Copyright 2012 Zoeller Co. All rights reserved.
  • Página 4 If the above checklist does not solve the problem, consult Zoeller Technical Service Department 1-(800) 928-PUMP - Do not attempt to service or otherwise disassemble pump. © Copyright 2012 Zoeller Co. All rights reserved.
  • Página 5: Location Selection

    Do not use wooden shims to level the pump unit! Ensure that nails, screws or other sharp objects do not puncture the pump unit! Level the pump unit to within 1/8" using hydraulic cement or similar material. SK2589 © Copyright 2012 Zoeller Co. All rights reserved.
  • Página 6 Alternate tightening nuts making sure bowl is level. DO NOT OVERTIGHTEN or china may DO NOT OVERTIGHTEN. Ballcock shank may split and void the warranty. crack. © Copyright 2012 Zoeller Co. All rights reserved.
  • Página 7 PVC pipe provided with the extension kit and cut it to length. See sketch at right. Set toilet aside. Toilet assembly is top heavy. Take special precautions to ensure that toilet does not tip over and break. SK2634 © Copyright 2012 Zoeller Co. All rights reserved.
  • Página 8 Flush the toilet and watch for proper operation. Listen AUX. INLET for the pump to start. The pump unit requires proper PUMP UNIT venting in order for toilet to flush. Check for leaks. SK2595 FLOOR LEVEL TO WITHIN 1/8" © Copyright 2012 Zoeller Co. All rights reserved.
  • Página 9 La reparación y el servicio deberán hacerse únicamente a través de una tomacorriente. Si no lo están, llame a un electricista calificado. estación de servicio autorizada por Zoeller Pump Company. (Consulte al POR PROTECCIÓN, SIEMPRE DESCONECTE LA BOMBA Y EL fabricante.)
  • Página 10: Garantía Limitada

    NO recomendamos. REVISE y pruebe el debido funcionamiento del sistema por lo menos cada 3 meses. © Copyright 2012 Zoeller Co. All rights reserved. © Copyright 2010 Zoeller Co. Todos los derechos reservados. 10 2...
  • Página 11: Configuraciones De Plomería Típicas

    Montaje de la válvula de llenado con tubo 150823 Montaje de la válvula de descarga 150824 Sapo con clip y cadena 150825 © Copyright 2012 Zoeller Co. All rights reserved. © Copyright 2010 Zoeller Co. Todos los derechos reservados.. 11 3...
  • Página 12 Si esta lista no le ayuda a identificar el problema, comuníquese con el Departamento de Servicio Técnico de Zoeller al teléfono +1 (502) 778-2731. No intente reparar ni desensamblar la bomba. © Copyright 2012 Zoeller Co. All rights reserved.
  • Página 13: Seleccione La Ubicación

    Nivele la bomba con una pendiente no mayor a 1/8" con ayuda de cemento hidráulico o algún otro material similar. SK2589 © Copyright 2012 Zoeller Co. All rights reserved. © Copyright 2010 Zoeller Co. Todos los derechos reservados. 13 5...
  • Página 14 NO APRIETE DEMASIADO PRECAUCIÓN NO APRIETE DEMASIADO. El vástago de PRECAUCIÓN quebrar la porcelana. la válvula de bola podría partirse y la garantía quedaría invalidada. © Copyright 2010 Zoeller Co. Todos los derechos reservados. © Copyright 2012 Zoeller Co. All rights reserved.
  • Página 15 La parte superior del inodoro es la más PRECAUCIÓN pesada. Tome precauciones especiales para asegurarse de que el inodoro no se caiga de lado y se rompa. SK2634 © Copyright 2012 Zoeller Co. All rights reserved. © Copyright 2010 Zoeller Co. Todos los derechos reservados. 15 7...
  • Página 16 Para que el inodoro funcione es necesario AUXILIAR BOMBA que la ventilación sea adecuada. Revise que no haya fugas. SK2595 PISO NIVELADO (±1/8") © Copyright 2010 Zoeller Co. Todos los derechos reservados. © Copyright 2012 Zoeller Co. All rights reserved.

Tabla de contenido