1. SECTION I | USER
1.1. GUIDE TO READING THE CODE
Number of compressors
2-4
Approximate cooling power (in Kw)
160÷350
The power value used to identify the model is approximate, for the exact value, identify the machine and consult the Technical Data.
1.2. AVAILABLE INSTALLATIONS
Set-up without pump or tank
Standard
Pump (main circuit)
Installation with pump
P1
Installation with increased static pressure pump
P2
Installation with double pump, including an automatically activated pump in stand-by
DP1
Installation with increased static pressure double pump, including an automatically activated pump in stand-by
DP2
Pump ("RC100" recovery circuit side) when available
Installation with pump
PR1
Installation with increased static pressure pump
PR2
Installation with double pump, including an automatically activated pump in stand-by
DPR1
Installation with increased static pressure double pump, including an automatically activated pump in stand-by
DPR2
Tank&Pump (main circuit)
Installation with pump and water buffer tank
ASP1
Installation with increased static pressure pump and water buffer tank
ASP2
Installation with double pump, including an automatically activated pump in stand-by and storage
ASDP1
Installation with increased static pressure double pump, including an automatically activated pump in stand-by and storage
ASDP2
1.3. EXAMPLE:
Example: EQRUSS 4350 ASP1
 Water production unit
 Cooling only
 Air-cooled
 4 Scroll-type hermetic compressors
 Super-silenced unit
 R32 refrigerant fluid
 Approximate nominal cooling capacity 350 kW
 Installation with pump and water buffer tank
1.4. MACHINE IDENTIFICATION
The units feature a serial number plate located on the electrical panel; it bears the machine identification data.
1.5. DECLARED CONDITIONS OF USE
EQRU-EQRUSS units are packaged air-cooled water chillers with axial fans respectively in high efficiency and super-silenced versions. EQRHU-EQRHUSS
units are packaged reversible heat pumps on the cooling circuit with evaporation/air cooled with axial fans respectively in high efficiency and super-si-
lenced versions. They are intended to be used in air conditioning systems where chilled (EQRU-EQRUSS) or hot and chilled (EQRHU-EQRHUSS) water is
required not for human consumption.
The units are designed for outdoor installation.