Descargar Imprimir esta página

Cherubini BLUE BUS TDS Serie Instrucciones página 40

Ocultar thumbs Ver también para BLUE BUS TDS Serie:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

ON
1
2
3
4
5
ON
1
2
3
4
5
ON
1
2
3
4
5
ON
1
2
3
4
5
ON
1
2
3
4
5
COMMANDS FROM THE CONTROL SWITCH
The Blue Bus TDS and the Blue Bus TDS RX control units make it possible to control the motor both
locally and centrally, when the instructions shown in the following pages are followed. The switches
must be interlocked mechanically and electrically to avoid the UP and DOWN arriving at the same time.
Both commands must be of the unstable type (push button). When the push buttons are released, the
contacts open. Should the rotation direction of the motor not correspond with the push buttons of the
switch (for example, if you press "UP" and the awning goes down), carry out the operation described
on the paragraph SETTING THE ROTATION DIRECTION OF THE MOTOR.
The motor can be controlled locally by means of a switch connected with the LOC CMD terminals of
the J3 connector of the control unit, by means of three wires (up, down, common) or by using a remote
control, if the module is of the Blue Bus TDS RX type.
By pressing one of the LOC CMD push buttons, the motor moves in the desired direction, until the limit
switch is reached and stops according to the settings of Dip Switch 1.
LOC CMD
DOWN
Up
In the Blue Bus TDS RX module, the remote
control controls the motor locally.
Dip Switch 3 ON
4 OFF
5 ON
Dip Switch 3 ON
4 ON
5 ON
Dip Switch 3 OFF
4 ON
5 OFF
Dip Switch 3 OFF
4 OFF
5 ON
Dip Switch 3 OFF
4 ON
5 ON
OPERATION OF LOCAL COMMANDS
LOC CMD
Rain sensor active: closing the (NO) switch causes the
ascent of the awning; the next opening of the switch
causes the descent of the awning.
Rain sensor active: closing the (NO) switch causes the
descent of the awning; the next opening of the switch
causes the ascent of the awning.
Wind sensor active: 15 Km/h wind speed threshold.
Wind sensor active: 30 Km/h wind speed threshold.
Wind sensor active: 45 Km/h wind speed threshold.
DSW1 OFF
ON
stop
1
2
3
4
5
LOC CMD
DSW1 ON
ON
1
2
3
4
5
40
/
DOWN
stop
UP

Publicidad

loading

Este manual también es adecuado para:

Blue bus tds rx serie