Spray Teflon lubricating oil on and between the parts of the centre bolt (B) while the tool is opening
and closing.
WARNING
Do not remove the centre bolt.
8.4.9
Dead man's handle
Check whether the deadman's handle returns to the neutral position.
Check the operation of the dead-man's handle. Have the Holmatro dealer repair the deadman's
handle if it doesn't function properly.
8.4.10
Carrying handle
Check the carrying handle for damage. Replace a damaged carrying handle.
Check if the carrying handle has been securely attached. Firmly re-tighten the knob.
8.5
Yearly dealer maintenance
We recommend having the equipment inspected, checked, set and tested once a year by a Holmatro
Certified Technician who has the appropriate knowledge and the necessary tools (see also section 1.7).
The Holmatro dealer can organize the yearly maintenance for you on a contract basis.
8.6
Long term storage
Ensure that the equipment is completely depressurized.
Store the equipment in a dry, well-ventilated area. Use additional preservatives on the external steel
parts.
9
Decommissioning/Recycling
At the end of its service life the equipment can be scrapped and recycled.
Make sure that the equipment is put out of order to avoid any use.
Check that the equipment does not contain any pressurized components.
Recycle the various materials used in the equipment such as steel, aluminium, NBR (Nitrile
Butadiene Rubber) and plastic.
Collect all dangerous substances separately and dispose of them in an environmentally responsible
way.
Consult the Holmatro dealer about recycling.