Descargar Imprimir esta página

Axis Communications Q1604 Guia De Instalacion página 15

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 75
Connectors
I/O Connector
4–pin terminal block
For an example diagram, see Connection Diagrams on page 16.
Function
Pin
1
0 V DC (-)
2
DC output
3
Digital Input
4
Digital
Output
Power Connector
2-pin terminal block for DC power input. Use a Safety Extra Low Voltage
(SELV) compliant limited power source (LPS) with either a rated output
power limited to ≤100 W or a rated output current limited to ≤5 A.
Audio Connector
3.5 mm audio
connectors (stereo)
AXIS Q1604 Network Camera
Notes
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
Connect to pin 1 to activate, or leave floating
(unconnected) to deactivate.
Connected to pin 1 when activated, floating
(unconnected) when deactivated. If used
with an inductive load, e.g. a relay, a diode
must be connected in parallel with the load,
for protection against voltage transients.
3
2
1
15
4
3
2
1
Specifications
3.3 V DC
Max load = 50 mA
0 to max 40 V DC
0 to max 40 V DC, open
drain, 100 mA

Publicidad

loading