3. On the remote control, press the "ON" button for one second. The
generator will perform the starting process automatically.
NOTE: Do not keep pressed the "ON" button on the remote control. Just press
for about a second.
On the first start attempt, if the generator fails, automatically it performs six new
attempts. Just wait. If the generator does not start within the six preprogrammed
attempts, you can press the "ON" button on the remote control again to do another
sequence of starts.
This generator has an automatic choke, so no lever action is required to make
easy the starting in a cold condition.
NOTE: The auto choke will not work if the battery is very low or damaged. In
this case you must close the choke manually and then pull the starter rope. The
battery recharges while the engine is running, you can also recharge it with the
engine off from the external socket on the panel, see chapter "Recharging the
battery from the charging port".
NOTE: If the generator remains off for more than 24 hours, the generator will
automatically go into "SLEEP" mode. To reactivate the remote control you must
press the START button on the generator. This function prevents battery
discharge.
NOTE: If the remote control does not work or works abnormally, replace the
battery.
OPD Function (Output power delayed). Up to 20 seconds after the starting, the
generator does not generate electricity in the sockets. This ensures that the
generator starts without supplying power to the connected equipment.
56