11. Cleaning and maintenance
m IMPORTANT! Before any cleaning, adjustment,
maintenance or repair work, disconnect the power
plug from the main power supply!
Machine care
The planer/thicknesser requires little maintenance.
The ball bearings are permanently lubricated.
After approx. ten operating hours, lubrication of the fol-
lowing parts is recommended:
• Bearing of the infeed and output roller
• Bearing of pulley and sprocket
The threaded spindle for height-adjustment of the
thicknessing table may only be treated with a dry lu-
bricant agent.
The table surfaces as well as the infeed and output
rollers must always be kept free from resin.
Regularly clean infeed and output rollers.
In order to avoid overheating of the motor, regularly
check the air openings for any dust sticking on.
After a longer period of use, it is recommended to have
the machine checked by an authorized dealer service.
Tool care:
Cutter block, clamping devices, knife supports and
knives must be regularly cleaned from resin, as a
clean tool improves the planing quality.
To this purpose, clamping devices, knife supports and
knives can be put in a common resin remover for 24
hours.
Resin from aluminium tools may only be removed with
cleaning liquids not being aggressive to this type of
metal.
Attention:
In case of a bad condition of the electrical system, the
performance can drop for a short period of time. Ask
a specialist.
12. Storage (Fig. 15)
Wrap the power cord (29) around the cable holder (30)
provided for this purpose. For the sliding cane the slid-
ing cane holders (28) are provided.
40 | GB
Store the equipment and accessories out of children's
reach in a dark and dry place at above freezing tem-
perature. The ideal storage temperature is between
5 and 30 °C.
Store the power tool in its original packaging.
Cover the electrical tool in order to protect it from dust
and moisture.
Store the operating manual with the electrical tool.
13. Electrical Connection
m WARNING! Electric shock! There is a risk of an
injury caused by electric shock!
Defective cable or plug may cause electric shock.
Avoid body contact with earth parts to protect yourself
from electric shocks.
m Operation is only allowed with a safety switch
against stray current (RCD max. stray current of
30mA).
Insert the plug of the electrical cable in a socket of
suitable shape, voltage and frequency complying with
current regulations.
Do not pull the service cable to pull the plug out of
socket.
The electric motor is connected in a ready-to-op-
erate state. The connection corresponds to the
relevant VDE and DIN regulations.
The mains connection at the customer's work
place and the extension cable used must corre-
spond to these regulations.
• The product meets the requirements of EN 61000-
3-11 and is subject to special connection conditions.
This means that use of the product at any freely se-
lectable connection point is not allowed.
• Given unfavourable conditions in the power sup-
ply the product can cause the voltage to fluctuate
temporarily.
• The product is intended solely for use at connec-
tion points that
a) do not exceed a maximum permitted supply im-
pedance Z
b) have a continuous current-carrying capacity of
the mains of at least 100 A per phase.
www.scheppach.com
= 0.367 Ω , or
max