3.5.5 Appliance's titanium condenser information
4.1 I Maintenance
• Before any maintenance work on the appliance, you must cut the electricity supply as there is
a risk of electric shock which may cause material damage, serious injury or even death.
• It is recommended that the appliance undergo general servicing at least on a yearly basis to
ensure its proper operation, maintain performance levels and prevent any possible failures.
These operations are carried out at the user's expense, by a qualified technician.
4.1.1 Monthly user maintenance
• Visually check the condensate drainage and check that the drainage tube is correctly positioned.
• Check for clogging in the filters:
- Manually remove any accumulated fibres and dust. Vacuum if necessary.
- Wash the filter with warm soapy water and leave to dry.
- If necessary, replace the filter by removing it as shown below (the filter is fixed by a bracket that must be unscrewed):
30
• Sensor: Measurement, in Pa, of the current differential pressure
• Air flow: Current air flow traversing through the appliance.
• Setpoint: Airflow setpoint.
• Inverter: Current use percentage of the electronic fan usage.
❹ Maintenance
that the fan is experiencing, used to calculate the real air flow
through the appliance.