9.4 Calibration
To maintain the specified precision of the measurement results, the instrument
must be recalibrated at regular intervals by our factory service. We recommend
a recalibration interval of one year. Send the appliance to the following address:
Benning Elektrotechnik & Elektronik GmbH & CO. KG
Service Centre
Robert-Bosch-Str. 20
D - 46397 Bocholt
10. Technical data of the measuring accessories
-
Standard: EN 61010-031,
-
Maximum rated voltage to earth ( ) and measuring category:
With push-on caps: 1000 V CAT III, 600 V CAT IV,
Without push-on caps: 1000 V CAT II,
-
Maximum rated current: 10 A,
-
Protective class II ( ), continuous double or reinforced insulation,
-
Contamination class: 2,
-
Length: 1.4 m, AWG 18,
-
Environmental conditions:
Maximum barometric elevation for making measurements: 2000 m,
Temperatures: 0 °C to + 50 °C, humidity 50 % to 80 %
-
Only use the test leads if in perfect condition and according to this manual,
since the protection provided could otherwise be impaired.
-
Throw the test leads out if the insulation is damaged or if there is a break in
the cable/ plug.
-
Do not touch the bare contact tips of the test leads. Only grab the area
appropriate for hands!
-
Insert the angled terminals in the testing or measuring device.