ENGLISH
If the safety thermostat trips, the appliance
needs to be reset to the initial working condi-
tions as follows.
Press button (A) located under the equipment
1)
to turn the electrical power supply back on.
To make the connection, connect the mains
line to the connection pipe of the appliance, fi t-
ting a shut-off tap (A) for the gas supply cut-off
when necessary. Easily accessible fi lters must
be fi tted downstream of the tap.
IMPORTANT:
be supplied with drinking water having the
characteristics shown in the table.
Description
150÷300 kPa (1.5÷3 bar)
Pressure
(*)
pH
7÷7.5
Conductivity
<200 mS/cm
9÷13°C (5÷7°d, 6.3÷8.8°e,
Hardness
90÷125 ppm)
Salt and metallic
ion content
Chlorides
<30 mg/l
Sulphates
<40 mg/l
Iron
<0.1 mg/l
Copper
<0.05 mg/l
Manganese
<0.05 mg/l
12
RESETTING THE APPLIANCE
WATER CONNECTION
The appliance must
Value
HANDLING AND INSTALLATION
A
(*) If the intake pressure exceeds 3 bar fi t a pres-
sure reducer.
A
3378610_inst_GB