Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal
pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• During initial start-up and after servicing, air in the
fittings can cause noise. After switching the jet on
and off about 15 times, the noise will stop.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Adjustment (see page 11)
To adjust the hot water limiter. Using a hot water limiter
in combination with a continuous flow water heater is
not recommended.
Fault
Mixer stiff
Mixer dripping
Water escaping at the threaded
base
Hot water temperature too low
Low flow with Select valve after
valve replacement
Select button stiff
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 70°C
max. 70°C / 4 min
Cause
- Cartridge defective, calcified
- Cartridge defective
- connection hoses not completely
screwed into basic body
- O-ring at the connection hose
defective.
- Hot water limiter incorrectly set
- Improper Select valve installed
- Select button soiled
Assembly (see page 4)
English
Dimensions (see page 18)
Flow diagram (see page 18)
Maintenance (see page 14)
The check valves must be checked regularly according
to DIN EN 1717 in accordance with national or
regional regulations (at least once a year).
Cleaning (see page 13)
Spare parts (see page 16)
Special accessories (order as an extra)
F12 extension #43333000 (see page 16 /
17)
Operation (see page 12)
• Hansgrohe recommends not to use as drinking water
the first half liter of water drawn in the morning or
after a prolonged period of non-use.
• Minor leaking may occur briefly at the spout when
opening the fitting via the lever.
• Use the lever to open the tap and set the desired
temperature. The water flow can be paused by
65°C
pressing the Select button on the face side of the
spout. When the tap is not used for a longer period
of time, f.e. when retiring at night or leaving the
house, it must be closed completely by means of the
lever.
Remedy
- Exchange cartridge
- Exchange cartridge
- Tighten connection hoses by hand
- Exchange O-ring
- Set hot water limiter
- Replace Select valve
(#98463000)
- Clean Select button and grease
(#9820100) O-ring