MAINTENANCE

Spark Arresting Muffler

The pole pruner is provided with a Spark Arrester System
p.n. 61280087 (Fig. 80) complying with the requirements of SAE
J335 standard; you can check the p.n. of the Spark Arrester
System on the muffler itself.
WARNING: A faulty or altered spark arrester system
screen can create a fire hazard.
80
Through normal use the screen can become dirty and should be
inspected weekly and cleaned as required.
To clean:
• Allow the muffler to cool.
• Remove the stop spring (A, Fig. 81).
• Remove the spark arrester screen (B).
• Clean and inspect the spark arrester screen.
• Reassemble components in reversed order of removal.
The Spark Arrester System needs a periodic and accurate
maintenance and cleaning, in particular:
- check periodically the spark arrester screen and substitute it
81
when holes, bends or deformations appear;
- check carefully if dust, debris or organic material is in contact
with parts of the Spark Arrester System; check especially the
gap between the muffler and the shield; clean it often with
tools or shop air.
WARNING: Do not operate your pole pruner if the
muffler is damaged, missing or modified. An
improperly maintained muffler will increase the risk of
fire and hearing loss.
82

Gear Housing

Every 30 working hours, remove screw (A, Fig. 82) on the gear
housing and check the quantity of grease. Use high quality
molybdenum bisulfide grease.