Troubleshooting must be carried out by a technical expert if the equipment temperature was
maintained upon commissioning (min. 16° C), the ambient temperatures are within the permissi-
ble limits and the air flow is correct.
In the event of a fire
 Shut down the refrigerating system and use a carbon dioxide or powder fire extinguisher to
fight the fire.
General information
 Only carry out freezing in compliance with the intended use described in the operating man-
ual.
 Do not obstruct the air circulation, i.e. do not close the lid and block the ventilation slots dur-
ing operation as otherwise the freezing process cannot be carried out properly.
 Protect cooling hoses and refrigerating clamps against damage.
 Only store, transport and operate the pipe freezing system in the installation position. Pro-
tect against impact, strong vibrations and falling. The system is suitable for portable use ac-
cording to class 7M2.
 The installation location must be dry and free from dust.
1.4
Special safety instructions and warnings for devices that use R290 refrigerant
(propane)
 According to DIN EN 378-1 the R290 refrigerant belongs to
safety group A3.
 The device is permanently sealed from a technical point of
view.
 The filling quantity of the refrigerant is less than 150g.
 Leave the device open for 5 minutes before commissioning.
 Leaks can cause the highly-flammable refrigerant to form an
explosive gas/air mixture. This might result in a fire and ex-
plosions with a subsequent fire risk.
 Therefore ignition sources (heat, sparks, open flames) should
be kept well away.
 Minimum clearances between the device and more easily in-
flammable objects should be 2 m on all sides.
 Do not use any items for defrosting other than those ap-
proved by the manufacturer.
 Never use devices without explosion protection signs for
cleaning in the cooling and machine rooms.
 Maintenance is only to be carried out without power, i.e. after
the power has been disconnected from the device.
 You must ensure that the device is disposed of correctly.
WARNING!
ENGLISH
15