REMOTE (1/2) menu
– – – R E MO T E [ 1 / 2 ] – – –
R E MO T E
O N
L O C A L F U N C T I O N
A L L K E Y S
P R E R O L L
5 S
R E M F F / R E W M O D E
F F / R E W
R E M S T O P S E L
E E
P B S T A R T D E L A Y
O F
S Y N C H R O N I Z A T I O N
O N
N E X T P A G E
P A G E B A C K
Memo
LOCAL FUNCTION:
• For controlling with the
REMOTE terminal, use
this menu item to select
the buttons on the unit to
be rendered operable.
REM FF/REM MODE:
• Use this menu item to
select the action to be
executed when an FF or
REW command is re-
ceived during playback.
(FF/FEW or search)
RM-G820 Settings
PREROLL
BUMP
COUNTER
MENU NO. 18 BUMP SELECT: Select PLAYER if the recorder used is not equipped with the BUMP func-
Notes
• Please do not use this unit as a recorder.
• It does not support AB roll editing.
• It does not support the following editing tasks:
Variable search
Slow-motion edit
CTL edit
• When performing jog operation using the editing remote controller, do it slowly. Otherwise, the VTR
may not be able to keep up.
• For certain controllers, the LEARN function will not work normally:
SONY : RM-450, PVE-500
Enabling the LEARN function:
Insert the tape with time code recorded till 23:59:00:00~00:01:00:00 into the BR-DV3000 before
activating the LEARN function.
• REM STOP SEL:
Use this menu item to set the operation mode upon reception of a
standby-on signal.
EE : EE mode (STOP mode)
PB : PLAYBACK mode (STILL mode)
• PB START DELAY:
Use this menu item to set the edit timing. If delay occurs at the
start of editing, correct this time discrepancy by adjusting the tim-
ing for starting playback.
0F
: No compensation. Usually, this option is selected.
1F to 15F : Delay by the number of frames set by the user. In the
case that the unit is connected to an editing remote
controller with no BUMP function, use this setting to
adjust editing precision.
• SYNCHRONIZATION
Use this menu item to turn on/off the synchronize function (BUMP)
to enhance editing precision.
OFF : No adjustments to synchronize.
ON
: Execute adjustments to synchronize. The editing operation
may take more time.
• CONTROLLER SEL [REMOTE (2/2) menu]
Use this menu item to set the type of controller connected.
☞
(
Page 60)
Set it to TYPE 1 when RM-G820 is used.
Setting the TC ADJUST item of the TIME CODE menu
To edit DV signals, set the timing of the time code output from BR-
DV3000 to the editing controller.
• Usually, it is set to "0FF".
• To edit DV signal with D9 VTR (equipped with SA-DV60), set it to
–2F.
: At least 7 sec is recommended.
: ON
: LCT (Player)
After setting has been done, activate the LEARN function.
tion.
E-51