Descargar Imprimir esta página

THERMOBILE ITA 35 R Manual Del Usuario página 16

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 42
English
1.2
Pictograms on the heater (fig. 2)
A
Pump pressure
1.3
Use in conformity with destination
The heater is designed for use on
construction sites, in poultry houses,
workshops, storage rooms, warehouses,
greenhouses and polyurethane tunnels and
to dry agricultural products and bulbs.
1.4
General instructions
Warning
Read this manual carefully before
you use the heater.
Keep this document near the
heater.
Do the procedures as written.
Do not lean on the heater.
Do not stand closer than 2 m
from the outlet of the heater.
Make sure there is sufficient air
for good combustion.
Keep all inflammable material
away from the heater.
Only do repair and maintenance
after the heater has cooled
sufficiently and the heater is
disconnected from the electric
power.
2
INTRODUCTION
2.1
Purpose
The heaters are indirectly fired heaters with
photocell control and connections for a room
thermostat and flue with raincover.
The heaters are tested at sea level and at a
temperature of 20 °C.
2.2
Operation principle
An electric motor drives a fan and fuel pump.
The pump draws the fuel from the tank to a
magnetic valve. The fan blows air into and
around the combustion chamber.
The magnetic valve opens 12 seconds after
switching on the heater and the fuel flows into
the nozzle.
A spark between the electrodes ignites the
1
6
16
atomised fuel and starts a flame. The light from
the flame activates a photocell. After the safety
time the ignition switches off. The magnetic
valve closes when you switch off the heater, or
as a result of a fault, the flame stops.
The fan runs until a thermostat switches the fan
off: the cooling cycle is complete.
2.3
2.4
3
3.1
1. Remove the packaging from the heater.
3.2
1. Make sure that the heater is placed
horizontally.
2. Fill the tank with fuel.
4
0
0 .
2
0
0 .
0
5
-
e r
. v
0
7
41.350.095 rev 01 - 2021
Main components (fig. 2 and 3)
A
Grill
B
Fan
C
Electric motor
D
Magnetic valve
E
Electrode (2x)
F
Burner head
G
Air slide valve
H
Photocell
I
After cooling safety thermostat
J
Combustion chamber/heat exchanger
K
Flue connection
L
Maximum thermostat
M
On / off switch I-0-II
N
Reset button
O
Identification plate
P
Air inlet burner
Q
Fuel pump
R
Connector for room thermostat
S
Cable with plug
T
Fuel filter
U
Push bar frame
Accessories
Flue with raincover
Room thermostat
Single outlet with duct
Manifold with duct
GETTING STARTED
Remove packaging
Installation
-
2
0
1 1
T I
/ A
T I
A
S
ITA 35 R

Publicidad

loading