Descargar Imprimir esta página

THERMOBILE ITA 35 R Manual Del Usuario página 18

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 42
English
5
MAINTENANCE
5.1
Maintenance table
After each winter season, record the
maintenance in the table at the back of this
book.
Description
Empty the tank and rinse the tank with paraffin.
Clean the filter in the filter cap of the tank.
Check the photocell for damage. Make sure the photocell is free from
dust and sediment.
Check the adjustment of the electrodes.
Replace the fuel filter.
Check the nozzle.
Clean the heat exchanger.
Hot
Do not touch the flue with raincover
and air outlet! Wait until the flue with
raincover and the air are cooled
down before maintenance.
5.2
General
Warning
Disconnect the electric power during
maintenance.
If the heater is not used for a long period:
1. Empty the tank, rinse the tank with
paraffin.
2. Fill the tank with diesel oil, to prevent
corrosion in the tank.
3. Let the heater burn for 3 minutes. This
protects the pump against corrosion.
4. Keep the burner head free from dust and
sediment.
A dirty burner head causes bad
combustion that makes soot and carbon
and damage to the burner chamber.
18
18
/i
5.3
A
Distance nozzle-swivel disc
B
Opening air inlet
C
Distance nozzle-electrode
5.4
Check the electrodes:
1. Remove the cover of the heater.
2. Remove the oil pipe (B).
3. Loosen the electrode cables (A).
4. Remove the screws (G).
5. Remove the burner head (F).
6. Clean and re-adjust the electrodes (C).
The electrodes must be free of dirt,
grease, fuel etc.
If the points of the electrodes are burned
too much and adjustment is impossible:
replace the electrodes.
7. Loosen the screw (F).
8. Re-adjust the electrodes.
Install the burner head in the reverse order.
40.020.005 - rev. 07 - 2011
41.350.095 rev 01 - 2021
Period
Yearly
X
X
X
X
X
X
Adjustment air inlet and
electrodes (fig. 6)
Electrodes (fig. 7)
Biennial
X
ITA/ITAS
ITA 35 R

Publicidad

loading