6- Quick programming
6.1- Procedure for facilitated gate leaf travel programming:
1
6
11
1-
Press the UP button once, the display will show LRNE
2-
Confirm with the OK button, the display will show APCH
3-
Press the APCH button
4-
The display reads CLS2, motor M2 closes until the mechanical stop
5-
After closing M2, M1 starts to close and the display shows CLS1
6-
After closing M1 the display shows LOC (operates the electric lock)
7-
M1 starts to open at slow speed and continues until the mechanical stop, the display will show OPN1
8-
M2 starts to open at slow speed and continues until the mechanical stop, the display will show OPN2
9-
M2 starts to close at cycle speed and then slows down and continues until the mechanical stop, the display will show CLS2
10-
M1 starts to close at cycle speed and then slows down and continues until the mechanical stop, the display will show CLS1
11-
The control panel runs a full gate leaf opening and closing cycle to save the current thresholds, the display will show 4 dots
12-
After closing, the display will show END, the procedure has been successfully completed.
The reduced procedure allows saving the travel, with distances for slowing down of 30% the total travel, while the gate leaf delays are fixed at 3 seconds for
opening and 6 seconds for closing.
6.2 Procedure for saving a remote control associated with button APCH:
1
x2
1- Press the UP button 2 times, the display will show RAD
2- Press the OK button, the display will show 1CH (indicating that the remote control button will be saved as AP/CH of the control panel)
3- Press the OK button, 4 dots will appear on the display, indicating that the control panel is waiting for a remote control button to be tapped (timeout 10
seconds)
4- After pressing the remote control button the display will show a 4-digit number: the first digit indicates association (1 controls the AP/CH input 2 controls
the pedestrian entrance or the second channel output) the other 3 indicate the memory cell occupied by the remote control (the first remote control oc-
cupies cell 001, the second one cell 002), the maximum capacity is 200 remote controls To save other remote controls repeat the procedure.
N.B.: The first saved remote control configures the control panel to accept only remote controls with a rolling code or only remote controls with a fixed 12-bit
code
30 30
2
3
7
8
12
2
3
4
5
9
10
4
5