6-
After closing M1 the display shows LOC (operates the electric lock)
7-
M1 starts to open at slow speed and continues until the mechanical stop, the display will show OPN1
8-
M2 starts to open at slow speed and continues until the mechanical stop, the display will show OPN2
9-
M2 starts to close at cycle speed and then slows down and continues until the mechanical stop, the display will show CLS2
10-
M1 starts to close at cycle speed and then slows down and continues until the mechanical stop, the display will show CLS1
11-
The control panel runs a full gate leaf opening and closing cycle to save the current thresholds, the display will show 4 dots
12-
After closing, the display will show END, the procedure has been successfully completed.
The reduced procedure allows saving the travel, with distances for slowing down of 30% the total travel, while the gate leaf delays are fixed at 3 seconds
for opening and 6 seconds for closing.
N.B.: If the direction of gate leaf movement is incorrect, press the ESC button, the control panel will exit programming and block gate movement. Modify
the electrical wiring harness of the gearmotors and repeat the procedure.
7.2 RAD: remote control management menu is divided into 4 parameters:
Description of RAD menu parameters:
D i s p l a y
Description
Message
1 CH
Used to save the remote control button corresponding to the input AP/CH
Used to save the remote control button corresponding to the input PED or output
2 CH
2CAN
Pressing the button on the remote control lets you compare and see where the
CTRL
memory cell has been saved.
Used to delete a remote control in the memory list or all the remote controls in
ERAS
the memory.
32 32
Press the
UP button
Premendo
1 time
1 volta UP
Press the
UP button
Premendo
2 times
2 volte UP
Press the
UP button
Premendo
3 times
3 volte UP
Display message after activating the remote control
1***
2***
1*** or 2***
After selecting the remote control from the list press OK and the
display will show OOOO to confirm deletion. To delete all the re-
mote controls select ALL between 200 and 001 and press OK, the
display will show 0000
EN