IV.
Technical Parameter
Model
Advised pool volume (m
Operating air temperature (℃)
Performance Condition: Air 26°C, Water 26°C, Humidity 80%
Heating capacity (kW)
C.O.P
C.O.P at 50% capacity
Performance Condition: Air 15°C, Water 26°C, Humidity 70%
Heating capacity (kW)
C.O.P
C.O.P at 50% capacity
Performance Condition: Air 35°C, Water 28°C, Humidity 80%
Cooling capacity (kW)
Rated input power
at air 15°C (kW)
Rated input current
at air 15°C (A)
Power supply
Advised water flux
Water pipe in-out Spec (mm)
Net Dimension LxWxH (mm)
Net Weight
(kg)
Notice:
This product can work well under air temp 0℃ ~ +43℃, efficiency will not be
1.
guaranteed out of this range. Please take into consideration that the pool heater
performance and parameters are different under various conditions.
2.
Related parameters are subject to adjustment periodically for technical improvement
without further notice. For details please refer to nameplate.
107248
3
)
14~28
6.0
9.5~5.9
8.5
4.3
5.9~4.4
5.8
2.2
0.29~1.0
1.26~4.2
(m³/h)
2~4
744×359×648
42
107249
20~35
0~43
8.0
9.1~5.6
8.0
6.0
5.9~4.1
5.9
3.3
0.34~1.4
1.48~6.0
230V/1 Ph/50Hz
2~4
50
864×359×648
46
7
107250
20~40
9.5
9.5~5.7
8.3
7.0
6.0~4.3
5.6
3.8
0.35~1.6
1.52~7.0
3~4
864×359×648
864×359×648
47
107844
30~55
12.5
10.5~5.9
9.2
9.0
5.9~4.2
5.8
4.9
0.36~2.1
1.57~8.7
4~6
49