VII. Operation instruction
Picture for keys
SYMBOL
Note:
1.
Switch on/off: In the power on state, press
the power is on, press
2.
You may set the desired water temperature from 12 to 40℃.
3.
The center of the screen shows the inlet pool temperature, when the up and
down keys are pressed, the digital flashing displays the set temperature.
4.
After you turn on the heat pump, the fan will start to run in 3 minutes. In
another 30 seconds, the compressor will start to run.
5.
During heating, the
light. During auto heating cooling,
DESIGNATION
Power ON/OFF
Press to power on or off the heat pump
Press to select Smart/Silence mode
Mode
Smart mode:100%-20% capacity
Silence mode:80%-20% capacity
Press to shift among Auto (12~40℃)
Heat/Cool/Auto
Heating (18~40℃) Cooling (12~30℃)
Up/ Down
Press to set desired water temperature
to turn it off.
will be light. During cooling,
OPERATION
to turn on the power. When
and
13
will be
will be both light.