Storage/winter protection
• Put the unit out of operation at water temperatures below 8 °C or, at the latest, when freezing temperatures are to
be expected.
• Drain and thoroughly clean the unit, check for damage.
• Remove, clean, dry and store all filters in a frost-free environment.
• Ensure that the storage place is inaccessible to children.
• Cover the filter container such that the ingress of rain water is excluded.
• Drain all hoses, pipes and connections as far as possible.
Malfunction remedy
Malfunction
The unit performance is not satisfactory
UVC lamp display is not lit
No water outlet from the pond inlet
Wear parts
• Filter media
• UVC lamp, quartz glass and O ring for quartz glass
Spare parts
The use of original parts from OASE ensures continued safe and reliable operation of the unit.
Please visit our website for spare parts drawings and spare parts.
www.oase.com/ersatzteile
Disposal
N O T E
Do not dispose of this unit with domestic waste.
• Render the unit unusable beforehand by cutting the cables and dispose of the unit via the return system
provided for this purpose.
• Dispose of UVC lamps by availing of the take-back system in place for this purpose.
Cause
Unit has been in operation only for a short time
Water extremely soiled
Excessive fish and animal population
Foam filters soiled
Quartz glass tube soiled
UVC lamp capacity exhausted
Power supply of Filtoclear-UVC not connected
UVC lamp defective
Connection defective
UVC overheated
Pump power supply not connected
Pond inlet blocked
Filter container/pump housing clogged
Remedy
The complete biological cleaning effect is only
achieved after several weeks
Remove algae and leaves from the pond,
change the water
Guide value: approx. 60 cm fish length in 1 m³3
pond water
Clean filters
Remove UVC and clean quartz glass
Replace the lamp after approx. 8,000 operating
hours
Connect UVC power plug
Replace the UVC lamp
Check electrical connection
UVC automatically switches on when cooled
down
Connect pump power supply
Clean pond inlet
Clean filter container/pump housing
- EN -