15. Technical specifications
Test voltage
Test voltage resolution
Test voltage accuracy
Polarity
Leakage current
Leakage current resolution
Leakage current accuracy
Display
Ripple
Measuring modes
Safety features
USB
Protocol
Bluetooth
Built-in chronometer
:
Up to 70,000 V.
:
100 V from 10 kV up to 70 kV.
10 V up to 9.99 kV.
:
± (2 % of nominal value ± 2 digits) with
500 μA load.
:
Negative voltage, ground positive.
:
Max. 500 μA.
:
1 μA.
:
± (2% of nominal value ± 2 digits).
:
Alphanumeric.
:
< 2%.
:
• Automatically configured tests, according to
standards IEC 60903, ASTM D120 and
ASTM F496-08
• Periodic tests for gloves class: 00, 0, 1, 2, 3
and 4
• "Pass / Fail" test
• Timed tests (within the limits of each
standard)
:
Remote control via Bluetooth.
Emergency stop buttons.
Self-detection of sparks.
Visual indicators (LEDs).
Sound indicator.
:
For configuration, control and download the
stored values.
:
Modbus.
:
For configuration, control and download the
stored values.
:
Up to 3 min., indication in mm:ss.
28