3.2 Adjusting the Sensor
3.2.1 Items to Check Before Making Sensor Adjustments (Linux)
The following error may appear while using this product.
Check the following items if this error appears.
・Check that light is not blocked from reaching the board surface or reflective tape.
・Check that the reflective tape is not dirty.
If the problem is not corrected despite making the above checks, In the operating
system you are using, perform adjustment in accordance with " Sensor Adjustment
Procedure " shown in Section 3.2.2.
3.2.2 Sensor Adjustment Procedure (Linux)
[1] Press the "OK" button on the "LSaDrv Touch Sensor Error" dialog box displayed on
the Linux screen.
[2] Start the sensor adjustment wizard.
1 Debian
Select [Applications] → [Education] → [LsCamWiz].
[3] The sensor adjustment wizard starts. Click the "All adjust" button.
[4] Wait a while. If the "LsCamWiz ERROR" message does not appear, sensor
adjustment was successful. If an error such as the following appears, click the "OK"
button and then perform adjustment again while referring to Section 3.2.1. If
adjustment is still not successful, the StarBoard unit may be defective.
[5] If adjustment was successful, click the "Exit" button.
* Note that just clicking the button does not complete the adjustment process.
[6] To save the adjustment result, click the "Yes" button.
This completes sensor adjustment.
After making adjustments, check that input can be performed normally.