Check the joints of the aspiration nipple are well placed and the nipple nut properly
adjusted.
Verify that the filling and emptying plugs are tight and with its seal.
SEAL CONNECTOR
PLUG AND FILLING SEAL
PLUG AND EMPTYING SEAL
CASING
DIFFUSER
TURBINE
12.3 The pump is stuck.
Remove the front casing of the pump,
open the pump and remove from the
turbine the object that is blocking the
pump.
Important:
Do
not
remove
the
turbine.
12.4 Water loss between the pump and the engine.
If you notice a loss of water between the
motor and the pump is very likely that the
mechanical seal is damaged. This may be
due to a working pump without water at
any time or simply the logical wear of both
parts of the seal. Contact your nearest
service center to replace the seal. The
seal replacement is not covered by the
guaranty unless it is defective of origin and
notified within 30 days.
51