Descargar Imprimir esta página

SICK Smart Light Tower SLT060-0B010J700 Instrucciones De Operación página 43

Ocultar thumbs Ver también para Smart Light Tower SLT060-0B010J700:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 48
8.2.1.2.3
8.2.1.2.4
8.2.1.2.5
8.2.1.3
Configuration via IO-Link master based on the IODD
8.2.1.4
Configuration via direct access to service and process data
9
Troubleshooting
8026183.1FJ5/2022-11-17 | SICK
Subject to change without notice
Diagnostics page
The current status of the SLT can be checked on the Diagnostics page. If the
device reports an error, it will be displayed here. The sending of IO-Link events can
also be deactivated here.
Identification page
The device identification details are displayed on the Identification page. An appli‐
cation-specific name and a device function name can be specified here.
Settings page
The language of the user interface can be selected on the SETTINGS page.
Diagnostics page
The current status of the SLT can be checked on the Diagnostics page. If the device
reports an error, it will be displayed here. The sending of IO-Link events can also be
deactivated here.
Identification page
The device identification details are displayed on the Identification page. An application-
specific name and a device function name can be specified here.
Settings page
The language of the user interface can be selected on the Settings page.
The following settings are possible:
Language: English/Englisch, German/Deutsch
Use the INFORMATION button to get more detailed information about the version of the
interface software.
Instead of the SiLink2 IO-Link master, other IO-Link masters can also be used to
configure the SLT. For example, the SIG200 IO-Link master (available at www.sick.com)
enables the use of a graphical user interface generated from the IODD (IO-Link device
description file) of the SLT. No SDD is necessary here, because the configuration is
done directly via the parameters described in the IODD. For more information on the
procedure, please refer to the SIG200 User Manual, which can also be downloaded at
www.sick.com.
The third option for configuring the SLT is to directly access the service and process
data via an IO-Link master or a PLC with a connected IO-Link master terminal without
using a graphical user interface. When using this type of configuration/control, informa‐
tion about the process data structure for control and service data (ISDUs) is required for
configuration.
NOTE
Detailed information can be found in the IO-Link description (8026795) and / or the
IODD description.
The Troubleshooting table indicates which measures are to be taken if the device stops
working.
OPERATING INSTRUCTIONS
O P E R A T I N G I N S T R U C T I O N S | SLT
en
43

Publicidad

loading

Este manual también es adecuado para:

Smart light buzzer slb060-0b010k70060759386076072