Descargar Imprimir esta página

SunPower SPR X Serie Instrucciones De Seguridad E Instalación página 10

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 67
Maxeon 3 112 cells AC Ready Solar Panel
(SPR-MAX3-XXX-R, SPR-MAX3-XXX-BLK-R, SPR-MAX3-XXX-COM-R)
0
150
50
TOP CLAMPS
Moun ng
Moun ng Configura on Diagram
Configura on
Descrip on
Front View
Back View
Long Side Moun ng,
Rails Perpendincular
to Moun ng Frame
Long Side Moun ng,
Point Supported
Long Side Moun ng,
Rails Parallel to
Moun ng Frame
Short Side Moun ng,
Rails Perpendicular to
Moun ng Frame
(End Mount)
Short Side Moun ng,
Point Supported
(End Mount)
Short Side Moun ng,
Rails Parallel to
Moun ng Frame
(End Mount)
1 In the cases where hybrid moun ng is necessary (combina on of long and short side moun ng), the lowest
design load values should be considered as allowable design load.
2 Test loads are for informa on purposes only, design loads should be considered for the project design.
3 Design Load considers 1.5 Factor of Safety, Test load = Design load x 1.5. Product Warranty covers only design
load values. The design loads listed in this table supersede all other loads that may be defined by other
par es, unless there is a formal authoriza on by Maxeon.
©June 2023 Maxeon Solar Technologies, Ltd. All rights reserved. Specifications included in this manual are subject to change without notice.
272
453
Measurement Tolerances are +/-3 mm for the Length and Width of the Module.
A - Ground Holes (4X Ø4.2mm)
B - Moun ng Holes (8X Ø6.8mm)
Moun ng Zone
Test Load
Design Load
Loca ons
(distance from corner
Downward/Upward
Downward/Upward
(Pa)
in mm)
50 - 150
+2700/-2700
+1800/-1800
150 - 272
+2400/-2400
+3600/-3600
+3600/-2800
+5400/-4200
272 - 453
+3600/-2400
453 - 710
+2400/-1600
50 - 150
+2700/-2700
+1800/-1800
150 - 272
+2400/-2400
+3600/-3600
+5400/-4200
272 - 453
+3600/-2800
453 - 710
+3600/-2400
+2400/-1600
50 - 150
+1800/-1800
+2700/-2700
150 - 272
+2400/-2400
+3600/-3600
272 - 453
+3600/-2800
+5400/-4200
453 - 710
+3600/-2400
+2400/-1600
+2700/-2700
+1800/-1800
0 - 350
+2700/-2700
+1800/-1800
0 - 350
0 - 350
+2700/-2700
+1800/-1800
Safety and Installation Instructions - Document 001-15497 Rev.AA
710
710
1100 mm
1300 mm
1656 mm
1812 mm
GEN 5.2 FRAME PROFILE
SIDE FRAME PROFILE
(Pa)
40 mm
32 mm
BOLTS
Moun ng
Moun ng Configura on Diagram
Configura on
Descrip on
Front View
Long Side Moun ng,
Rails Perpendincular
to Moun ng Frame
Long Side Moun ng,
Point Supported
4 Rails must not be under the junc on box.
6 Bo om flange moun ng.
7 Rails indicates posi oning of the clamp and not the rails.
MAXEON SOLAR TECHNOLOGIES, LTD.
453
272
150
50
B
A
END FRAME PROFILE
40 mm
24 mm
Moun ng Zone
Test Load
Loca ons
Downward/Upward
(distance from corner
Back View
(Pa)
in mm)
1300mm Holes
+5400/-5400
1100mm Holes
+5400/-5400
1300mm Holes
+5400/-5400
1100mm Holes
+5400/-5400
0
Design Load
Downward/Upward
(Pa)
+3600/-3600
+3600/-3600
+3600/-3600
+3600/-3600

Publicidad

loading