KEY SWITCH
INDEX
CH2
KEY SWITCH TYPE 1 [AUTO-PP]\[PED]:
By activating the key switch on channel CH1 (key to the right), the AUTO-
PP (open-close) command is enabled, while by activating channel CH2
(key to the left), the PED (pedestrian opening) command is enabled.
KEY SWITCH TYPE 2 [OPEN]\[CLOSE]:
By activating the key switch on channel CH1 (key to the right), the OPEN
(open only) command is enabled, while by activating channel CH2 (key to
the left), the CLOSE (close only) command is enabled.
KEY SWITCH TYPE 3 [AUTO-PP]\[STOP]:
By activating the key switch on channel CH1 (key to the right), the AUTO-
PP (open-close) command is enabled, while by activating channel CH2
(key to the left), the STOP (stop automation) command is enabled. After
a STOP, The user will have to send a subsequent command to restore
operation of the automation.
INTERFACE I/O
IN
OUT
I/O INTERFACE TYPE 1 In=[AUTO-PP]\[PED] Out=AUX:
Input
Using the inputs IN1-COM or IN2-COM-COM will enable the following commands:
IN1-COM:
(NO optically insulated input) enables the command
Auto-PP (open-close)
IN2-COM:
(NO optically insulated input) enables the PED command
(pedestrian opening)
Output
There are two outputs set to AUX function (which can be enabled simultaneously by
each
remote control encoded as AUX - monostable 3" ON):
24V+
+24V
output (20mA max)
24V-
-24V
output
NO:
Clean NO contact output (24V
C:
Clean contact output (common)
I/O INTERFACE TYPE 2 In=[OPEN]\[CLOSE] Out=AUX:
Input
Using the inputs IN1-COM or IN2-COM-COM will enable the following commands:
IN1-COM:
(NO optically insulated input) enables the command
OPEN (opening only)
IN2-COM:
(NO optically insulated input) enables the command
CLOSE (closing only)
Output
There are two outputs set to AUX function (which can be enabled simultaneously by
each remote control encoded as AUX - monostable 3" ON):
24V+
+ Output FOR indicator light 24V
24V-
- Output for indicator light 24V
CH1
INTERFACE I/O
1A max)
(20mA max)
NO:
Clean NO contact output (24V
C:
Clean contact output (common)
I/O INTERFACE TYPE 3 In=[AUTP-PP]\[STOP] Out=INDICATOR LIGHT:
Input
Using the inputs IN1-COM or IN2-COM-COM will enable the following commands:
IN1-COM:
(NO optically insulated input) enables the command
Auto-PP (open-close)
IN2-COM:
(NO optically insulated input) enables the command
STOP (stop automation)
Output
There are two outputs set to INDICATOR LIGHT function that are enabled
simultaneously, signalling the status of automation:
24V+
+ Output FOR indicator light 24V
24V-
- Output for indicator light 24V
NO:
Voltage free NO contact output (24V
C: Voltage free contact output (common)
Flashing light output
= moving gate
Output enabled (ON)
= open gate
Output disabled (OFF)
= closed gate
I/O INTERFACE TYPE 4 In=[AUTP-PP]\[PED] Out=INDICATOR LIGHT:
Input
Using the inputs IN1-COM or IN2-COM-COM will enable the following commands:
IN1-COM:
(NO optically insulated input) enables the command
Auto-PP (open-close)
IN2-COM:
(NO optically insulated input) enables the command
PED (pedestrian opening)
Output
There are two outputs set to INDICATOR LIGHT function that are enabled
simultaneously, signalling the status of automation:
24V+
+ Output FOR indicator light 24V
24V-
- Output for indicator light 24V
NO:
Voltage free NO contact output (24V
C:
Voltage free contact output (common)
Flashing light output
= moving gate
Output enabled (ON)
= open gate
Output disabled (OFF)
= closed gate
FLASHING LIGHT:
The operation of each flashing light is defined by the control unit based on
the settings on the configurable parameters.
FUNCTIONAL CHARACTERISTICS (PARAMETERS)
AUTOMATIC OPERATION:
Using both the remote control and the accessory control devices connected
to the BUS with AUTO-PP function to open/close the gate, operation will
be as follows:
the first impulse opens the gate until the programmed stroke ends or until
the gate reaches its opening limit stop; the second impulse closes the gate;
if another impulse is sent before the end of the stroke or before one of the
two limit stops has been reached, the control unit reverses the movement
direction during both opening and closing.
1
2
3
4
5
6
7
8
9
O
N
DIP-SWITCH 1 OFF = Automatic Operation
NOTE: A variation of the dip-switches requires pressing the RESET
button on the control unit to enable the new setting.
STEP-BY-STEP OPERATION:
Using both the remote control and the accessory control devices connected
to the BUS with AUTO-PP function to open/close the gate, operation will
be as follows:
the first impulse opens the gate until the programmed stroke ends or until
the gate reaches its opening limit stop; the second impulse closes the gate;
if another impulse is sent before the end of the stroke or before the opening
limit stop has been reached, the control unit stops the movement (even if
you have previously programmed the pause time). An additional command
activates a reverse strokein the opposite direction; if you send a command
before the end of the stroke or the closing limit stop, the control unit always
stops movement. A further command activates a reverse stroke.
O
1
2
3
4
5
6
7
8
9
N
DIP-SWITCH 1 ON = Step-by-Step Operation
NOTE: A variation of the dip-switches requires pressing the RESET
button on the control unit to enable the new setting.