Descargar Imprimir esta página

Bosch HDI8054 Serie Manual De Instalación página 20

Ocultar thumbs Ver también para HDI8054 Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

3. Once theairhasbeenpurged fromthesupply lines,
verify thattheburner l ightswithin four(4)seconds.
Afterburner l ights, t urnknobtotheoffposition.
4. Test e achrangetop burner inthisfashion. C allService
if anyofthe burners donotlight.
Test flame characteristics
on the low setting:
,
2.
3.
,
Push in and turn the knob to the flame symbol until the
burner ignites.
Turn knob quickly to the low setting.
Verify that the flame is:
A minimum height (approximately
114"or 6 mm).
Steady (The flame should not go out, lift or blow off
of the burner. It should carry over, or surround, the
entire burner.)
The right color. It should be blue with an inner and
outer cone. See Figure 24: Checking Flame Char-
acteristics for more information.
Test each rangetop burner in this fashion. If any flame
goes out, does not carry over properly or is too large,
contact service.
Test flame characteristics
on the high setting:
,
2.
3.
,
Push in and turn the knob to the flame symbol until the
burner ignites.
Turn knob to the high setting.
Verify that the flame is:
Steady (The flame should not go out, lift or blow off
of the burner. It should carry over, or surround, the
entire burner.)
The right color. It should be blue with an inner and
outer cone. See Figure 24: Checking Flame Char-
acteristics for more information.
Test each rangetop burner in this fashion. If any flame
burns yellow or does not carry over properly, contact
service.
Some yellow streaking is normal during the initial start-up.
Allow unit to operate 4-5 minutes and re-evaluate.
When correct color, carryover and size are verified, the
burner testing is complete.
If any of the tests do not result as explained above, contact
Bosch service for assistance. Otherwise, the installation is
complete at this time.
Yellow Flames:
Further adjustment is required.
Yellow Tips on Outer Cones:
Normal for LP Gas.
Soft Blue Flames:
Normal for Natural Gas.
If the flame is completely or mostly yellow, verify that the
regulator is set for the correct fuel. After adjustment, retest.
English 18

Publicidad

loading

Este manual también es adecuado para:

Hdip054 serieHgi8054 serieHgip054 serie