Precautions before installation
Make sure that dirt from the silicone-based seal material does not adhere within the toilet bowl.
Secure the space required for toilet installation and at the same time, check door opening/closing for possible interference.
Turn on the electricity and water supply for the product only after all other installation work is complete.
Do not damage the connection components on the water supply hose.
The water supply pressure ranges from 7.25 PSI (0.05 MPa) <dynamic> - 108.78 PSI (0.75 MPa) <static>. Use the unit within
the said pressure range. If the water supply pressure is low, toilet bowl cleaning may not be performed.
The product automatically measures water pressure conditions in the operating environment during toilet bowl cleaning and
adjusts the volume of toilet bowl flush water used.
The temperature of the water supply should be within a range of 0 to 35 °C(32-95 °F). Make sure the temperature is within this range.
Working ambient temperature is within the range of 0 to 40 °C(32-104 °F). Make sure the temperature is within this range.
Prepare an outlet position in advance that conforms to the regulations in your country.
Make sure before installation that the water supply source and water drain pipe are in the specified positions according to the
diagram.
If there is a gap between the discharge pipe and floor, fill it with mold-resistant silicone-based seal material (Mediseal).
Doing otherwise may cause water to leak downstairs.
Perform wiring correctly according to this product's specifications (rated power 15 A or more, 120 V AC (60 Hz)).
* Power supply, rated power consumption is indicated on the label of this product.
The power cord is 1.2 m (3.93 ft) long.
Check that the outlet is provided in a location appropriate for this length.
Because a water flow test is conducted on each product at the factory, water may remain inside the product.
This water does not indicate a problem with the product.
Water supply 1/2" NPT
235 mm±10 mm
(9-2/8 )
140 mm±10 mm
(5-4/8 )
60 mm±10 mm
215 mm±10 mm
(2-3/8 )
(8-4/8 )
Water supply 1/2" NPT
Tubo de descarga de PVC
8
Before installing the product, be sure to
completely wash out any dirt, sand, etc.
from inside the water supply pipe.
305 mm±10 mm
(12 )
9