Descargar Imprimir esta página

Bosch GTC600C Instrucciones De Funcionamiento Y Seguridad página 11

Publicidad

Idiomas disponibles

Idiomas disponibles

Thermal imaging Camera
Dimensions (length × width × height)
Protection rating (excluding rechargeable batteries, in
the vertical position)
Recommended ambient temperature during charging
Permitted ambient temperatures
• During operation
• During storage with a rechargeable battery
• During storage without a rechargeable battery
Rechargeable batteries
(Bosch 10.8V/12V Max lithium-ion pack)
Chargers
Battery life 10.8 V/12 V Max
Relative humidity (non-condensing)
Indoor or outdoor use:
Wet location use:
a. In accordance with standard VDI 5585 (average)
b. In accordance with standard VDI 5585
c. At an ambient temperature of 68 to 73°F (20 to 23°C) and an emissivity of > 0.999,
measuring distance: 11.8 in (0.3 m), operating time: > 5 min, aperture of 60 mm
d. Plus use-dependent deviation (e.g. reflection, distance, ambient temperature)
e. Only non-conductive deposits occur, whereby occasional temporary conductivity caused
by condensation is expected.
f. Depends on battery in use.
g. At an ambient temperature of 68 to 86°F (20 to 30°C)
The serial number 4 on the type plate (shown in Fig. 1) is used to clearly identify your mea-
suring tool.
Specifications
GTC600C
4.53 x 4.01 x 9.09 in
(115 × 102 × 231 mm)
IP54
32 to 95°F (0 to +35°C)
• 14....+122°F (–10...+50°C)
• -4....+122°F (–20...+50°C)
• -4....+158°F (–20...+70°C)
BAT414 (2.0 Ah), BAT420 (4.0 Ah),
GBA12V30 (3.0 Ah), GBA12V60 (6.0 Ah)
BC330, BC430, GAX1218V-30, GAL 12V-20
5.0 h
90%
Indoors only
No
-11-

Publicidad

loading

Este manual también es adecuado para:

3 601 k83 510