GB
6.4
Charger / batteries
Charger ASC55, 220 - 240 VAC, 3A, CAS
Order no. 11385
Li-Power battery 18 V / 2.0 Ah CAS
Order no. 11386
7
Maintenance and inspection
7.1
Safety measures
i
Important:
The operator must provide any protective clothing that may be required.
Who can carry out maintenance and inspection work?
» Normal maintenance work can be carried out by trained operating personnel.
7.2
Maintenance and inspection table
Interval
Assembly
As re-
Outside of filling station
quired
Container
Monthly
Line/hose system
Filter seal at 90 degree
Annually
bend
7.3
Troubleshooting
Fault
Reduced pump output
Pump does not run when bat-
tery inserted
34
Action
Remove adhering dirt and diesel fuel.
Visual check for damage
Check hoses for cracks and porosity, check valves for leaks
(replace defective parts).
Clean (see picture)
Possible cause
Hoses are blocked or kinked
Air bubbles in the liquid
Filter seal at 90 degree bend
clogged
Battery voltage too low
Battery empty
Battery not inserted correctly
Li-Power battery 18 V / 4.0 Ah CAS
Order no. 11387
Li-HD battery 18 V / 8.0 Ah CAS
Order no. 11388
Solution
Check hoses
Leave the tank to stand for a few
minutes
Clean (see picture)
Charge battery
Charge battery
Insert battery correctly