tions and/or cause respiratory illnesses in the user or in
people in the near vicinity.
Certain dusts, such as oak or beech dust, are classified as
carcinogenic, especially in conjunction with wood treatment
additives (chromate, wood preservative). Materials contain-
ing asbestos may only be machined by specialists.
– Use a dust extraction system that is suitable for the ma-
terial wherever possible.
– Provide good ventilation at the workplace.
– It is advisable to wear a P2 filter class breathing mask.
The regulations on the material being machined that apply in
the country of use must be observed.
Avoid dust accumulation at the workplace. Dust can
u
easily ignite.
Operation
Do not load the power tool so heavily that it comes to a
u
stop.
Remove the battery from the power tool before carry-
u
ing out work on the power tool (e.g. maintenance,
changing tool, etc.). The battery should also be re-
moved for transport and storage. There is risk of injury
from unintentionally pressing the on/off switch.
Exercise caution when cutting slots in structural walls;
u
see the "Information on structural design" section.
Clamp the workpiece if it is not secure under its own
u
weight.
If the power tool has been subjected to a heavy load,
u
continue to run it at no-load for several minutes to
cool down the accessory.
Do not use the power tool with a cut-off stand.
u
Do not touch grinding and cutting discs until they have
u
cooled down. The discs can become very hot while work-
ing.
If the power tool becomes electrostatically charged, the
built-in electronics will switch the power tool off. Press the
on/off switch (4) again to restart the power tool.
Start-Up
Switching on/off
To start the power tool, push the on/off switch (4) forward.
To lock the on/off switch (4) in position, push the on/off
switch (4) forward and down until it clicks into place.
To switch off the power tool, release the on/off switch (4);
or, if the switch is locked, briefly push the on/off switch (4)
backward and down and then release it.
Always check abrasive tools before using them. The
u
abrasive tool must be fitted properly and be able to
move freely. Carry out a test run for at least one
minute with no load. Do not use abrasive tools that are
damaged, run untrue or vibrate during use. Damaged
abrasive tools can burst apart and cause injuries.
Bosch Power Tools
Practical advice
Rough grinding
Always use the protective guard for grinding (9) when
u
rough grinding with bonded abrasives.
Never use cutting discs for rough grinding.
u
When rough grinding, the protective guard for
u
cutting (10) or the protective guard for grinding (9)
with a fitted cover for cutting (13) can impact the
workpiece and lead to a loss of control.
The best rough grinding results are achieved with a set angle
of 30° to 40°. Move the power tool back and forth with mod-
erate pressure. This will ensure that the workpiece does not
become too hot or discolour and that grooves are not
formed.
The protective guard for cutting (10) or the protective
u
guard for grinding (9) with a fitted cover for cutting (13)
must be used when using bonded discs which are ap-
proved for cutting and grinding.
Surface grinding with flap disc
Always use the protective guard for grinding (9) when
u
grinding with the flap disc.
The flap disc (accessory) enables you to machine curved
surfaces and profiles. Flap discs have a considerably longer
service life, lower noise levels and lower grinding temperat-
ures than conventional grinding discs.
Surface grinding with sanding disc
Always fit the hand guard (18) when working with the
u
rubber sanding pad (19).
Grinding with a sanding disc can be done without a protect-
ive guard.
See the graphics page for fitting instructions.
Cup brush/disc brush/conical brush
Always use the protective guard for grinding (9) when
u
brushing with disc brushes. Brushing with cup
brushes/conical brushes can be performed without
the protective guard.
Always fit the hand guard (18) when working with the
u
cup brush or conical brush.
The wires of the disc brush can get caught on the pro-
u
tective guard and break, if the maximum permitted di-
mensions of the disc brushes are exceeded.
See the graphics page for fitting instructions.
Cutting Metal
For cutting metal with bonded cutting discs or dia-
u
mond cutting discs, always use the protective guard
for cutting (10) or the protective guard for
grinding (9) with a fitted cover for cutting (13).
When using the protective guard for grinding (9) for
u
cutting work with bonded cutting discs, there is an in-
creased risk of being exposed to sparks, particles and
disc fragments if the disc breaks.
When carrying out abrasive cutting, use a moderate feed
that is suited to the material being machined. Do not exert
English | 27
1 609 92A 76P | (22.05.2023)