EN
children and persons of impaired mental, sensory and intellectual functions. Place the unit in such
a way that the mains plug can be reached at any time. Ensure that the power supply to the unit
corresponds to that specified on the identification plate!
If it is not possible to place the appliance on a fireproof surface, place it on a non-flammable, heat-
resistant pad with a minimum thickness of 15 mm and extending beyond the outline of the stove
(see the technical data table) plus an additional 150 mm from the front.
ASSEMBLY OF THE DEVICE
IMPORTANT: Installation, electrical and water connection as well as functional testing and
maintenance must be performed only by an authorized, qualified person. Install the product in
accordance with local, national and state laws and regulations.
Chimney/ventilation:
Minimum required temperature class of insulated steel - T400 (or higher) - resistant to soot ignition.
The chimney should have a single, mandatory inspection hatch ("a" in the picture below)/inspection
flap (b), and the entire installation should be in accordance with EN1856-1 and -2.
The chimney installation should be airtight, vertical, without any narrowings, made of a smoke-
impermeable material, thermally insulated (to avoid condensation or cooling the smoke) and
resistant to normal mechanical stress coming with time - recommended AISI 304 chimney steel with
a round section. The installation should be separated from flammable or combustible materials by
an air gap or adequately insulated with materials - see standard EN1443. The chimney opening must
be in the same room as the unit or at most in an adjacent room. Underneath must be a soot and
condensate collection chamber - accessible through a waterproof, metal hatch.
•
Flat roof
A - 0.5 m
B - distance >2 m
C - distance <2 m