LP Conversion
Instructions
GAS SUPPLY
• With the installation of this conversion kit,
the cooktop should operate on LP gas at 10"
of water column pressure.
• The pressure regulator must be connected in series
with the manifold of the cooktop and must remain
in series with the supply line. For proper operation,
the maximum inlet pressure to the regulator must
be no more than 14" water column pressure for
LP gas.
• When checking the regulator, the inlet pressure
must be at least Z" greater than the regulator output
setting. If the regulator is set for 10" of water column
pressure, the inlet pressure must be at least 11:'
I M PO RTAN T - Discon
nect
the cooktop
a
nd
theindividual
shut-off valve fromthegassupply piping
systemduring any pressure t esting ofthat systemattest
pressures greater t hani/2psig. I solate thecooktop from
thegassupply piping systemby closing theindividual
manual shut-off valve tothecooktop during any pressure
testing ofthegassupply piping systemattest pressures
equal toorgreater than1/2psig.
TURN OFF GAS AND
ELECTRIC SUPPLY
BEFORE YOU BEGIN, TURN OFF THE GAS SUPPLY AT
THE SHUT-OFF VALVE. DISCONNECT THE ELECTRICAL
SUPPLY FROM THE COOKTOR
Shut-off valve
i
I
/#"J
Electrical
supply
I_1CONVERT THE PRESSURE REGULATOR
[] Locate the pressure regulator under the front
of the cooktop.
[] Remove the nut from the pressure regulator with
an adjustable wrench.
Natural
gas
LP gas
[] Twist and remove the conversion plug from the inside
of the nut. Flipthe conversion plug over; then insert,
twist and lock it back into place in the nut.
Natural
gas
LP gas
I
Nut
I
[]
Reinstall the nut onto the regulator.
[]
Apply the LPConversion
label next to the Rating Plate.