ASSEMBLY
To reduce the risk of injury, always
WARNING
unplug tool before changing or
removing accessories. Only use accessories
specifically recommended for this tool. Others
may be hazardous. To reduce the risk of injury,
do not remove or attach accessory tips until tool
has cooled to room temperature.
Configuration Mode
1. To enter configuration mode, press and hold the
and
buttons then move the switch from the
(0) position to the (1) position.
2. The tool will turn on and the configuration option
C0 will display on the LCD.
3. Press the
or
available options (C0, C1, C2, C3, C4, and C5).
4. Press the
button to select the desired configu-
ration option. When selected, the configuration
option number (C0, C1, C2, etc) will flash.
5. Set the configuration option as desired.
6. Press the
button to save your selection and
return to configuration mode.
7. To exit configuration mode, push the switch to the
(0) position.
NOTE: The function locked will appear when trying
to go above set temperature or air volume.
(C0) Selecting the Temperature Unit
Use the C0 screen to set the desired temperature
unit - Celsius (ºC) or Fahrenheit (ºF).
1. Enter configuration mode.
2. While in the C0 screen, use the
and
buttons to set the de-
sired temperature unit
3. Press the
button to save your
selection and return to configu-
ration mode.
4. To exit configuration mode, push the switch to the
(0) position.
(C1) Setting the Lowest Operating
Temperature Level
Use the C1 screen to set the lowest operating tem-
perature level.
1. Enter configuration mode.
2. While in the C1 screen, use the
and
buttons to set the lowest
operating temperature level.
3. Press the
button to save your
selection and return to configuration mode.
4. To exit configuration mode, push the switch to the
(0) position.
(C2) Setting the Highest Operating
Temperature Level
Use the C2 screen to set the highest operating
temperature level.
1. Enter configuration mode.
2. While in the C2 screen, use the
and
buttons to set the highest
operating temperature level.
3. Press the
button to save your
selection and return to configuration mode.
4. To exit configuration mode, push the switch to the
(0) position.
button to cycle through the
(C3) Setting the Lowest Air Flow Level
Use the C3 screen to set the lowest air flow level.
1. Enter configuration mode.
2. While in the C3 screen, use the
and
buttons to set the lowest
air flow level.
3. Press the
button to save your
selection and return to configuration mode.
4. To exit configuration mode, push the switch to the
(0) position.
(C4) Setting the Highest Air Flow Level
Use the C4 screen to set the highest air flow level.
1. Enter configuration mode.
2. While in the C4 screen, use the
and
buttons to set the highest
air flow level.
3. Press the
button to save your
selection and return to configuration mode.
4. To exit configuration mode, push the switch to the
(0) position.
(C5) Setting the ECO Mode
The ECO mode (1) is activated automatically by the
motion sensor and uses less energy.
The standby mode (2) needs to be manually set. The
fan turns off to conserve electricity but keeps heating
element active.
Use the C5 screen to set the ECO mode.
1. Enter configuration mode.
2. While in the C5 screen, use
the
and
buttons to set
the ECO mode (0, 1 or 2).
(0) = Off (default)
(1) = On (5 to 60 second delay before activation)
(2) = On (activated when tool tilted to 90º)
3. Press the
button to save your selection and
return to configuration mode.
4. To exit configuration mode, push the switch to the
(0) position.
Resetting Configuration
1. Slide the switch to the (0) position.
2. Press and hold the
tons.
3. Slide the switch to the (1) posi-
tion.
4. Configuration settings will be
reset to factory defaults.
Configuration Default
C0
Celsius
C1
80ºC (lowest temperature level)
C2
650ºC (highest temperature level)
C3
7.1 CFM (lowest air flow level)
C4
17.7 CFM (highest air flow level)
C5
ECO mode off
Installing/Removing Nozzles
1. To install, slide the nozzle onto the heat gun nose.
2. Adjust heat, air flow, distance and length of ap-
plication as necessary.
3. To remove, allow tool to cool to room temperature,
then pull nozzle away from tool.
6