Before installing
the dryer
Unpacking
the appliance
The dryer is very heavy. Do not
lift it by yourself.
Do not lift the
appliance
by projecting
components
(e.g. door) - due to
risk of breakage.
Remove the appliance
packaging
carefully to prevent
damage to the surfaces.
Check the dryer for transportation
damage. Do not connect a dryer which
is visibly damaged. If in doubt, contact
your dealer.
Supplied
components
For U.S.A.
The dryer is supplied without
a power cord. The power cord
must be connected
by qualified
persons only.
After removing the packaging,
immediately
remove any objects
from the drum.
The dryer is delivered as a complete
unit. The operating instructions and
supplied accessories can be found in
the drum.
Installation
location
Do not install the dryer:
-
outdoors
-
in an environment with dripping
water,
-
near flammable materials,
-
in rooms which are at risk of frost,
-
in rooms which may contain gas
or other fuels,
-
in cupboards with Iockable doors
or in alcoves.
The installation room must be well
ventilated, otherwise the dryer will
operate below optimum performance.
Do not operate the dryer at
temperatures above 104°F (40°C) and
below 41 °F (5°C). Low temperatures
affect the automatic program sequence
and may prolong the drying times.
The installation surface for the dryer
must be clean, level and firm. Do not
install the appliance on carpets!
Compensate for uneven floors with the
height-adjustable feet.
Install the dryer and level side to side
and front to back. Use a bubble level.
Never remove the height-adjustable
feet!
The size of the installation area
depends on the dimensions of the
dryer. Ensure that there is adequate
room for the swivel range of the door!
a
Dimension
Weight
a
27.0" (686 mm)
125 Ibs
b
31.8" (808 mm)
(56 kg)
with
c
37.2" (945 mm)
packaging
d
19,7" (500 mm)/
143 Ibs
angle
170-180°
(64 kg)
If installing the dryer in a closet, observe
the minimum distances according to
the following table:
Minimum Installation Clearances
Closet
Sides
0" (0 ram)
Top
12" (305 mm)
Rear*
0" (0 mm)
* as closeto wallas ventingwill allow.
Important information concerning
minimum distances:
-
Depending on the location of the
exhaust air connection, an
additional minimum distance of
51/2inch (14 cm) must be provided
on this side for pipes/brackets (see
page 7).
-
Distances above the indicated
minimum dimensions reduce the
risk of mold formation behind the
appliance.
-
Additional distances reduce noise
transmission.
-
Additional distances facilitate
installation and service.
-
If the dryer is installed in a small
room, the doors of the room must
be fitted with vents of a specified
minimum size.
The dryer door is delivered with hinges
on the right. If required, the door hinges
can be switched to the left side.
If the door hinges are to be changed