Electrical
connection
Power cord must be connected
by a qualified person only.
Connect
to individual
Branch
Circuit.
Do not use an adapter.
Do not use an extension
cord.
Do not remove ground prong.
For CANADA
Your dryer comes with a power supply
cord, CSA listed in Canada.
The Bosch dryer requires a 4 wire
receptacle.
When installing the receptacle for the
dryer cord, ensure that the power
supply cord is accessible when the
dryer is in the installed position.
The power cord should only be
replaced by a qualified person. Use a
4_wire power supply cord (see
electrical connection U.S.A. below).
For U.S.A.
Your dryer comes without a power
supply cord. The power cord must
meet the following requirements:
-
UL listed in the USA
-
208 - 240 volt rated (minimum)
-
30 amps
-
Type SRDT or DRT (UL 2158)
-
Five feet long (minimum)
Power cord must be connected
by a licensed electrician
only.
Use only a U.L. approved
30 amp power cord with strain
relief clamp -
note manufacturer's
instructions.
Do not plug end of power cord
into a iive receptacle
before
connecting
power cord to
appliance_erminals
and closing
junction/splitter
box as described
below.
Do not reuse old power cord.
Cord must have closed loop or
upturned
end wire terminating
connectors.
Do not make a sharp bend or crimp
wiring/conductor
at connections.
Only a 4-conductor cord shall
be used when the appliance is
installed in a mobile home, in a
recreational vehicle, in a new branch
circuit installation or an area where
the local codes do not permit
grounding through the neutral.
Connecting
4-wire
power
supply
cord
1. Remove the screws from the cover
of the terminal block located at the
top rear of the appliance.
1
1PIE} ....
2
1 -
terminalbl0ck
2-
groundingstrap
3 -
Anglebracketfor strain reliefdamp
2. Loosen the bottom screw of the
grounding strap. Place the screw
to the GROUND location.
Straighten the grounding strap and
hang loosely.
3. Fix the strain relief clamp to the
angle bracket. Tighten the nut.
4,
,
6.
7,
,
,
Loosen the 2 screws labeled L and
the screw labeled 1t in the terminal
block, and the screw of the
GROUND terminal.
Thread the 4 wire cable through the
U.L strain relief clamp.
Tighten the screws (2.5 Nm) of the
U.L strain relief clamp so that the
power cord cannot be moved.
Attach the power cord ground
conductor (green) to the GROUND
terminal. Tighten the screw (2.5
Nm) so that the ground conductor
is held securely in place.
Attach the 2 power cord outer
conductors (red and black) to the 2
terminals labeled L and the
remaining power cord conductor
(white) to the terminal labeled N.
Tighten all 3 screws (3 Nm) so that
the power conductors are held
securely in place.
_[
.......
_
10. Check the U.L strain relief clamp
to make sure that it is tight and
cannot be turned.
Replace the cover on the terminal
block and fasten in place.
Make sure that the U.L strain relief
clamp is outside the cover!
The appliance is now ready to be
plugged into the 4-wire receptacle of
the power rating.
Connecting
3-wire
power
supply
cord
1. Remove the screws from the cover
of the terminal block located at the
top rear of the appliance.